![Rigol DSG5000 Series Programming Manual Download Page 52](http://html.mh-extra.com/html/rigol/dsg5000-series/dsg5000-series_programming-manual_1460929052.webp)
•
When the modulation source of AM is set to "Int", this command is invalid. You
can send the
command to set or query the AM
modulation source.
Return Format
The query returns 50, 600, or 100k.
Example
:AM:EXT:IMP 600 /*Sets the impedance of the AM external
modulation to 600Ω.*/
:AM:EXT:IMP? /*The query returns 600.*/
3.1.7
[:SOURce][:RF]:FM Commands
3.1.7.1
[:SOURce][:RF]:FM:DEViation
Syntax
[:SOURce][:RF
<
channel>
]:FM:DEViation
<
value>[<unit>]
[:SOURce][:RF
<
channel>
]:FM:DEViation?
Description
Sets the FM frequency offset of the specified channel.
Queries the FM frequency offset of the specified channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<value>
Real
0.1 Hz to 4 MHz
10 kHz
<unit>
Discrete
Hz|kHz|MHz|GHz
Hz
Remarks
•
When <value> is set in "Number" form, the default unit is Hz. For example,
20000. Besides, <value> can can also be set in " Unit" form, For
example, 20kHz.
•
The default unit of the return value is Hz.