RIGOL
Chapter 1 Disassembly and Assembly
1-8
DSG3000B Service Guide
Disassemble the Front Protective Covers
Figure 1-6 Disassemble Front Protective Covers
Part Description:
①
4 screws (M4*8 torx pan head screw, used for fastening the front protective covers)
②
4 screws (M4*10 torx pan head screw, used for fastening the front protective covers)
Disassembly Steps:
1.
Use the T20 screwdriver to remove 8 screws that secure the front protective covers.
2.
Remove the four front protective covers gently.
Note:
When assembling the front protective covers, pay attention to the mounting position of front
protective covers. The front protective cover with 2 ribs on it should be mounted at the top; whereas
the front protective cover with one rib on it should be mounted at the bottom.
①
①
①
①
②
②
②
②