:MEASure:R2FDelay
Syntax 1
:MEASure:R2FDelay [<chanA>,<chanB>]
Description 1
Measures the delay (rising edge-falling edge) between the two specified source channels.
Syntax 2
:MEASure:R2FDelay? [<chanA>,<chanB>]
Description 2
Measures and queries the delay (rising edge-falling edge) between the two specified source channels. The
default unit is s.
Parameter
Name
Type
Range
Default
<chanA>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
--
<chanB>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
--
Remarks
Before making measurements, turn on the channels to be measured.
When [<chanA>,<chanB>] is omitted, this command will be applied to Source A (refer to
the :MEASure:SETup:DSA command) and Source B (refer to the :MEASure:SETup:DSB command) of
delay measurement currently set by default.
Return Format
The query returns the measurement results in scientific notation. When the measurement results are invalid,
the query returns 9.9e37.
:MEASure:R2FDelay:SAVerage
:MEASure:R2FDelay:SCURrent
:MEASure:R2FDelay:SDEViation
:MEASure:R2FDelay:SMAXimum
:MEASure:R2FDelay:SMINimum
Syntax 1
:MEASure:R2FDelay:SAVerage [<chanA>,<chanB>]
:MEASure:R2FDelay:SCURrent [<chanA>,<chanB>]
:MEASure:R2FDelay:SDEViation [<chanA>,<chanB>]
:MEASure:R2FDelay:SMAXimum [<chanA>,<chanB>]
:MEASure:R2FDelay:SMINimum [<chanA>,<chanB>]
Description 1
Measures the delay (rising edge-falling edge) between the two specified source channels and enables the
statistic function of the measurement results.
Syntax 2
:MEASure:R2FDelay:SAVerage? [<chanA>,<chanB>]
:MEASure:R2FDelay:SCURrent? [<chanA>,<chanB>]
:MEASure:R2FDelay:SDEViation? [<chanA>,<chanB>]
:MEASure:R2FDelay:SMAXimum? [<chanA>,<chanB>]
:MEASure:R2FDelay:SMINimum? [<chanA>,<chanB>]