
Chapter 5 To Trigger the Oscilloscope
RIGOL
DS2000E User’s Guide
5-41
SPI Trigger
Trigger on the data pattern on the specified edge. When using SPI trigger, you need
to specify the SCL and SDA data sources. Below is the SPI bus data transmission
diagram.
Serial Data Line Buffer
(SPIxRXB)
Shift Register
SPIxSR
SPI Buffer
SPIxBUF
Serial Data Line Buffer
(SPIxRXB)
Shift Register
SPIxSR
Serial Transmission Buffer
(SPIxTXB
)
SPI Buffer
SPIxBUF
Serial Transmission Buffer
(SPIxTXB)
Highest Bit
Lowest Bit
Highest Bit
Lowest Bit
SDIx
SDOx
SDIx
SDOx
Processor 1[SPI Host]
Processor 2[SPI Slave]
SCKx
Serial Clock
SCKx
Figure 5-15 SPI bus data transmission diagram
Trigger Type:
Press Type to open the trigger type list. Rotate
and press down
to select
"SPI". At this point, the trigger setting information is displayed at the upper right
corner of the screen. For example,
. The trigger type is SPI trigger;
the trigger source is CH1; the trigger level is 0.00 V.
Source Selection:
Press SCL and SDA to specify the data sources of SCL and SDA respectively. They
can be set to CH1 or CH2. For the details, please refer to the introduction in "
Source". The current trigger source is displayed at the upper right corner of the
screen.
Note: Select channel with signal input as trigger source to obtain stable trigger.
Summary of Contents for DS2000E Series
Page 1: ...RIGOL User s Guide DS2000E Series Digital Oscilloscope Oct 2017 RIGOL TECHNOLOGIES INC...
Page 2: ......
Page 22: ......
Page 62: ......
Page 72: ......
Page 82: ......
Page 198: ......
Page 212: ......
Page 238: ......
Page 258: ......
Page 261: ...Chapter 14 Remote Control RIGOL DS2000E User s Guide 14 3 3 4 5 6...
Page 268: ......
Page 283: ...Index RIGOL DS2000E User s Guide 3 X Y 3 4 X Y mode 6 37 Y Cursor 6 29 Y T 3 4...