4.8.11
:OUTPut:OVP:CLEar
Syntax
:OUTPut:OVP:CLEar
[<
source>]
Description
Clears an overvoltage protection (OVP) event occurred on the specified channel.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CH1|CH2|CH3}
-
Remarks
•
Before executing the command, make sure to remove the condition that caused
the overvoltage protection on the specified channel (you can either decrease the
output voltage to below the OVP level or increase the OVP level to be greater
than the output voltage).
•
If <source> is omitted, the command clears an OVP event that occurred on the
current channel.
•
[:SOURce[<n>]]:VOLTage:PROTection:CLEar
to clear an OVP
event that occurred on the specified channel and enable the channel output.
•
to query whether an
OVP event has occurred on the specified channel.
Return Format
None.
Examples
:OUTP:OVP:CLE CH1 /*Clears an OVP event that occurred on CH1.*/
4.8.12
:OUTPut:OVP[:STATe]
Syntax
:OUTPut:OVP[:STATe]
[<
source>,]<bool>
:OUTPut:OVP[:STATe]?
[<
source>]
Description
Sets or queries the on/off state of the overvoltage protection (OVP) function of the
specified channel.
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.