26
Pipe ID Control System. RF096-35/55-100 Series
RF096-35/55-100 [Revision 1.0.0] 12.12.2018
This byte specifies the timeout for the data stream of the serial response. If the
multiply responses are expected for every request sent by the converter, then the timeout
applies to all these messages.
12.4. Communication between PLC and system
Communication between PLC and system:
Area
byte
Data from PLC to System
Data from System to PLC
Description
Var Type
Description
Var Type
0
Calibration diameter
Real
Last diameter read average
Real
4
Real
Last diameter read minimum
Real
8
Real
Last diameter read maximum
Real
12
Measurement position (from a zero
point of a pipe)
Real
Real
16
Int
Int
18
Int
Int
20
Int
Int
22
Int
Int
24.0
Start calibration command
Bool
Calibration running
Bool
24.1
Bool
Calibration Done
Bool
24.2
Bool
Calibration error
Bool
24.3
Start measure command
Bool
Measure running
Bool
24.4
Bool
Measure Done
Bool
24.5
Bool
Measure error
Bool
24.6
New data transfer
Bool
New data transfer request read
Bool
24.7
Bool
New transfer data read
Bool
25.0
Abort measure
Bool
System error
Bool
25.1
Move to zero
Bool
Move to zero running
Bool
25.2
Bool
Move to zero Done
Bool
25.3
Bool
Move to zero error
Bool
25.4
Bool
Bool
25.5
Bool
Bool
25.6
Bool
Bool
25.7
Bool
Bool
12.4.1. General information
Every system error of the pipe control system must set the
System error
variable.
If this bit is raised up during any measurement, every cycle will be interrupted and
measurement results will not be read.
If for any reason PLC sets the
Abort measure
variable during the measurement
cycle, the pipe control system must finish the running procedure and move a laser sensor
into a safe position. This can be done if the operator checks for any anomaly during the
measurement cycle.