for Type EF 1112

 

as Flow Control Unit ZR, PN 25 

 

1.0 

Safety instructions 

 1.1 

Proper  use

 

 

Any improper use, intervention in the design and deviation from the design data automatically 
lead to termination of the warranty. The float-controlled condensate trap is designed for the 
discharge of condensate from steam, compressed air and pressure gas systems. Any other 
use is not permissible. The manufacturer is not liable for dam age resulting from any other 
use. The user or operator bears the risk in this case. This also applies analogously to 
incorrect assembly, startup, use and maintenance. 

 
1.2 

Warnings and symbols 

 

There is a risk of personal injury due to escaping operating medium as well as because of 
pressure, temperature and weight. Failure to comply with these warnings may lead to accidents. 
Follow the instructions in this operating manual. 
The operator must ensure that this operating manual and, if necessary, other relevant 
documents are available on site. 
Only trained or instructed personnel may be assigned to handling this 
equipment. Any mode of operation that may impair safety must be avoided. 

 

 

2.0 

General description and use 

 

Design of the condensate trap

 

 
 

1  

Housing cover 

 

2  

Housing gasket 

 

3  

Housing with connections 

5    Set of screws with nuts 

 

7    Float control 
8      Supporting 

structure with 
rotary slide valve 

 

9  

Float with fork 

 

10    Bush 

 

11    Set of Seals 

 

12    Sight glass 

 

13    Set of screws with nuts 

 

14    RWG-Frame 

 

16   Control screw 

 

17    RWG-Seals 

Fig.1 

 
 
 

2.2 

Identification, operating limits on rating plate or housing 