background image

General Information

Glass break detector «Steklo-2» (hereinafter, the Detector) is intended 

for detecting destruction of the following types of flat glass:

- customary glass with a thickness 2.5 … 8 mm;
- patterned glass with thickness 3.5 … 7 mm;

- laminated glass with polymer film, 

having area not less than 0.1 m

2

 (with length of any side not less than 

0.3 m), as well as hollow glass blocks with the following alarm message 
transmission to the control panel. The Detector comprises LED indicator 
for the Detector state displaying.

The Detector is supplied by the CP via alarm loop (hereinafter, AL) 

with input voltage range 10 … 30 V DC.

Operating temperature: from minus 20 to 45 

0

С.

Ambient class: Boreal Climate.
The Detector is designed for continuous operation around a clock.

Principal Technical Characteristics

Maximum detection range of the Detector under the impact on the 

protected glass, inserted into a framework – not less than 6 m.

The Detector operates at two frequencies.

The Detector provides it’s sensitivity  adjustment.

Warm-up time – not more than 30 sec.
Consumption current in standby mode (during «Norm» message 

generation) is not more than 1 mA at AL voltage 10 … 30 V DС.

The Detector informative capacity:
a) «Norm»

 message;

b) «Alarm» message.
«Norm» message is generated during all security period of the Detector 

operation in absence of destroying impacts on the protected glass by 
creation current in AL with the rate, corresponding to consumption current 
in standby mode. «Norm» state is displayed by LED lighting absence.

The Detector generates an «Alarm» message after registration of 

destroying impacts on the protected glass by increasing current in AL, 
whereupon supply voltage rate decreases till the level not more than  

5.2 V. Upon that, the current rate in the Detector should not exceed 

 

35 mA. LED indicator should light steadily.

ATTENTION!

 It is allowed to hook the Detector only in circuits with 

current limiting till the level not exceeding 35 mA. Connection of the 
Detector to power source without limiting resistor (1 k

Ω

) is absolutely 

forbidden.

Detection of the glass sheet destruction probability is not less than 0.9.
The Detector provides IP rating IP30.

Dimensions, not more than 80 х 80 х 35 mm.

Weight of the Detector is not more than 0.1 kg.
Mean time to failure in «Norm» mode – not less than 60 000 hours.

The Detector average life – not less than 8 years.

Scope of Delivery

Each Detector unit package contains the items listed in Table 1.
Table 1

Name

QNT

Glass break detector «Steklo-2»
Assessories set:
Testing ball
Mounting set:

Screw 1-3х20.016 

Glass break detector «Steklo-2». Installation Guide

1 pc.

1 pc.*

2 pcs.

1 copy

* – Single for 26 detectors

Installation

Examples of the Detector installation are shown in Figures 5 – 10, 

fixation marking – in Figure 1.

When choosing place of the Detector installation at the secured object, 

it is necessary to take into account the following requirements:

- possibility of the Detector installation on any of side walls  

(Figure 6) or opposite wall (Figure 7), on the room ceiling (Figures 5 

 

and  8),  as  well  as  on  partition  between  secured  glass  and  curtains 
(Figure 9);

- the Detector detection zone orientation (Figure 3);

- it is allowed to use the Detector simultaneoully with active ultrasonic 

detectors;

- all segments of the secured glass should be within the visibility 

range of the Detector;

- masking of the Detector by curtains is forbidden, as it leads to the 

Detector sensitivity loss;

GLASS BREAK 

DETECTOR

«

STEKLO-2

»

Figure 1

Installation Guide

Figure 2

Top view

Side view

Figure 3 – GB detection zone pattern

Microphone 

orientation

Microphone 

orientation

Steel ball

ø

 

 

21 ... 22 mm

Inclination 

angle 

30 ... 70

0

35 cm

Glass

R 6m

90

0

R 6m

+Input- +Output-

CP

To the CP 

terminal element

(56 ± 0.5) mm

2 fixation holes (for 3 mm screw)

Figure 4

Adjustment

The Detector adjustment is fulfilled as follows:
- open the Detector cover;
- set DIP-switches 1, 2 and 3 in ON position;

- suspend a steel ball 21 – 22 mm in diameter on a 35 cm long 

thread near the farthest part of the monitored glass, as it is shown in  
Figure 4. Deliver indestructible blow to the most distant place of the 
secured glass. Recommended deflection angles are listed in Table 2, 

for hollow glass blocks the inclination angle is 45°;

Table 2

Glass Thickness, mm

<3

3...4

4...5

5...6

6...7

>8

Ball deflection angle for ordinary 

and patterned glass, 

0

30

35

40

45

50

55

Ball deflection angle for 

laminated glass, 

0

45

50

55

60

65

70

- if LED indicator is not lighting after test blows, the Detector sensitivity 

should be increased by DIP-switches «1» and «2»

 (See Table 3);

Table 3

DIP-switch Position

Detector Mode of Operation

1

2

3

ON

OFF

ON

OFF

ON

ON

OFF

OFF

ON

ON

ON

ON

Sensitivity (detection 

range)

minimum

+6 dB

+14 dB

+20 dB (maximum)

ON

OFF

Adjustment

Standby mode

- distance between the Detector and farest point of the secured 

surface should not exceed 6 m.

Connection

Connection diagramm is shown in Figure 2.