General Information
Combined PIR + glass break detector «Orlan-D» (hereinafter, the Detector)
is designed for application as a component of security systems.
The Detector has the following two independent detection channels:
- Glass break channel (hereinafter, GB channel);
- Passive infrared channel (hereinafter, PIR channel).
GB channel is intended for detecting destruction of engineering structures
made of plate glasses, double- and triple-pane glasses with an area of not less
than 0.1 m
2
(with any side length not less than 0.3 m), as well as glass bricks.
PIR channel is assigned for detecting intrusion into protected area of closed
premises. PIR channel provides wide angle detection zone. The Detector is
resistant to movement of pets with weigh up to 20 kg with temperature contrast
∆
t = 8
о
C (smooth-coated cats and dogs) and pets with weigh up to 40 kg with
temperature contrast
∆
t = 6
о
C (long-hair cats and dogs).
The Detector generates Tamper message at it’s cover opening by an alarm
loop (AL) or microswitch contacts opening.
The Detector is resistant to the impacts of ambient light, radio noise, as well
as disturbance from small animals: mice, rats, birds in cages if a distance to
them is not less than 2.5 m.
The Detector can be installed on the wall or in the corner of the room. Wall or
ceiling mounting by means of swivel bracket (supplied) is also possible.
Features
Sensing element of detection channels:
- PIR channel – dual-element pyrodetector;
- GB channel – microphone.
- Microprocessor-based signal processing.
- Spherical lens ensures high detectability level.
- Self-test mode.
- Alarm at PIR and GB channels memorization (Alarm memory).
- Possibility of PIR and GB channels sensitivity modes choosing.
- Possibility of LED indication disabling.
- Pet movement resistance.
- Protection against ingress of insects to the pyrodetector.
- Possibility of swivel bracket using for the detection zone position alignment.
The Detector specifications are listed in Table 1. PIR detection zone pattern
is shown in Figire 1. GB detection zone pattern is shown in Figure 2.
Table 1
Parameter
Value
PIR channel detection zone
12 х 10 m
8 long-range zones, 7 middle-range,
4 short-range, 2 anti-sabotage
GB channel maximum detection range, not
less than
6 m
Output GB and PIR channels contacts:
- voltage, maximum
- current, maximum
72 V
30 mА
Sensitivity:
- GB channel (High Sens)
- PIR channel
selactable:
m7 dB/+14 dB/+21 dB
high/normal
Alarm message duration, not less than
2 sec
Minimum area of protected glass
0.1 m
2
Warm-up time after energizing, not more than
60 sec
Operating temperature
minus 20
о
С ... +45
о
С
Relative humidity at +25
о
C without moisture
condensation
90 %
IP rating
IP30
Dimensions, maximum
126 х 70 х 55 mm
Weight, maximum
150 g
COMBINED PIR + GLASS
BREAK DETECTOR
«ORLAN-D»
Figure 2 – GB Channel Detection Zone Pattern
Field of Application
The Detector can be installed in flats, shops, museums, offices and other
closed premises.
Choosing Place of Installation
When choosing the Detector installation place, it is advisable to take note of
the fact that the detection zone may be screened by non-transparent objects
(curtains, houseplants, cabinets, bookcases, etc.), as well as by glass and mesh
partitions. There must be no windows, air conditioners, space heaters or heating
radiators in the PIR detection zone.
Recommended installation height is 2.3 m. Distance between the Detector and
the farthest point of the monitored glass should not exceed 6 m. The Detector
microphone should be oriented strictly towards the protected surface of a glass
construction. In case of 1 m
2
area monitoring, maximal distance to the Detector
should be increased up to 9 m.
The Detector wires should be laid at a distance not less than 1 m from power
supply cables.
Scope of Delivery
Each Detector unit package contains items listed in Table 2.
Table 2
Name
QNT
Combined PIR + glass break detector «Orlan-D»
Accessories set:
Swivel bracket
Screw nut «SORMAT» 5х25
Screw 3-3х30.016
Testing ball
Combined PIR + glass break detector «Orlan-D». Installation Guide
1 pc.
1 pc.
2 pcs.
2 pcs.
1 pc.*
1 copy
* Supplied optionally
The Detector Installation
- Unfasten the latch through the opening, which is situated downside the
detector case by means of screwdriver and put off the detector cover (see
Figure 3).
- In case of mounting without swivel bracket, put off the PCB by means of
pushing up it’s fixing arm on the base.
- Drill the holes for wiring and fastening the detector (see Figure 3).
- Choose the place of installation, mark places for fastening holes in
compliance with fastening holes position on the Detector base (swivel bracket),
drill holes in the wall.
- Pass the wire through the mounting holes in the base leaving enough wire
inside the case for connection to the Detector terminals.
- Fasten the base (or swivel bracket) at the chosen place.
- In case of swivel bracket using, reverse the cap screw from the swivel
bracket sphere. Fit the square bulge of the swivel bracket external sphere with
the corresponded opening on the detector base (see Figure 3). Plug in the
screw to the opening in the top of the detector base and fix the connection by
the screw without tightening.
- Set the base in desired position and tighten the screw to ensure the base
stable fastening.
- Put the cover with PCB on the base by combining bulge on the PCB with
recess on the base, then click-up the PCB by fixing arm.
Installation Guide
0
10 m
Side view
Top view
90
0
2.3 m
0
10 m
Figure 1 – PIR Channel Detection Zone Pattern
Microphone
psitioning
90
о
R
R
180
о
Side view
Top view
Figure 3 –Detector Base and Swivel Bracket
For the wall
mounting
Openings
for wires
For corner
mounting
For fastening the base to the
swivel bracket
PCB
fixing
arm
Opening for the
cover latch
Base
Plug
Nut
Sphere
Swivel
bracket
Screw
Swivel Bracket
Components