1 Introduction
The detectors «Foton-10M», «Foton-10M-01» (hereinafter, the
detector) is designed for detecting intrusion into the protected space
and generating an alarm message by opening the relay output contacts.
The detector ensures tamper protection. The «Tamper» message is
generated by opening microswitch contacts.
The detector is resistant to the exposure of ambient light and radio
interference, as well as to influence of small pets: mice, rats, birds,
placed in the cages at a distance not less than 2.5 m.
The detector is compact, attractive, simple in installation, and
servicing. It is possible to install the detector on the wall or in the
corner of the room.
2 Features
- Dual-element pyrodetector.
- Spherical Fresnel lens.
- Wide-angle detection zone.
- Immunity to insects intrusion to the pyrodetector.
- Microprocessor-based signal processing.
- Extended speed range, detecteed by Foton-10M-01 (0.1 – 3 m/sec).
- Selectable modes of testing, sensitivity, alarm memory and led
indication.
- Self-test mode.
- The detector is rated for switching to the DC power source with
output voltage 10 – 15 V.
- Possibility to install the detector on the swivel bracket (supplied)
for the detection zone repositioning.
- Case tamper protection.
3 Specifications
Table 1
Parameter
Value
Detection zone
12 x10 m
Power supply, V DC
10 – 15 V, current 15 mА
Tamper output contacts
Closed – «Norm» message, current
30 mА, voltage 72 V
Alarm message duration
Not less than 2 sec
Detection zones
9 long-range, 5 short-range
Sensitivity
Chosen by switch «1» (position 1/2)
Installation height range
2 – 5 m
Operating temperature range
minus 30 … + 50
0
С
Relative humidity
95 % under 25
0
С without moisture
condensation
IP rating
IP41
Dimensions, max
90 х 60 х 50 mm
Weight, max
60 g
Detection zone pattern is shown in Figure 1.
PASSIVE INFRARED
DETECTORS
«FOTON-10M»,
«FOTON-10M-01»
Installation Guide
Table 2
Name
Version
-
-01
Passive infrared detector «Foton-10M»
Passive infrared detector «Foton-10M-01»
Swivel bracket
Screw 3-3х30.016
Passive infrared detector «Foton-10M»,
«Foton-10M-01». Installation Guide
1 pc.
1 pc.
2 pcs.
1 copy
1 pc.
1 pc.
2 pcs.
1 copy
6 Choosing the Place of Installation
The detector is designed for operation in the closed areas. When
choosing the detector installation place, take note of the fact that the
detection zone may be limited by non-transparent objects (curtains,
houseplants, cabinets, bookcases, etc), as well as glass and mesh
partitions. There must be no windows, air conditioners, space heaters
or heating radiators in the detector visibility range.
Recommended installation height:
- without swivel bracket – 2 – 3 m;
- by means of swivel bracket – 2.3 – 3 m (on condition that the
detector tilt is adjusted).
Power supply and alarm loop wires should be located far enough
from power feed cables.
7 The Detector Installation
- Unfasten the latch through the opening, which is situated downside
the detector case by means of screwdriver and put off the detector
cover (Figure 2).
- When installing the detector without swivel bracket it is necessary
to put off the PCB by means of pushing up it’s fixing arm.
Figure 2 – The Detector Base and the Swivel Bracket
- Drill the holes in the base of the detector for wiring and fastening
the detector (Figure 2).
- Choose the place of installation, mark the places for mounting
holes with the regard to detector base (or swivel bracket) openings,
drill the holes in the wall.
- Pass the wire through the mounting holes in the base, leave several
centimeters of installation wire for it’s fastening inside the case.
- Fix the base of the detector case on the wall (swivel bracket) at
the chosen place.
- Put the PCB on its place.
Note
– In case of swivel bracket using, unscrew the cap screw
M3x20 from the swivel bracket sphere. Holding the assembled swivel
bracket, fit the square bulge of the swivel bracket external sphere with
the corresponded opening on the detector base. Turn the detector
base to the left full point and then to the right. Plug in the screw to
the opening in the top of the detector base and fix the connection by
the screw. Set the detector base to the operating position and fasten
it with the cap screw M3x20.
In case of the detector installation at 2 – 5 m height with keeping
12 m detection zone, it is necessary:
- After the detector fastening to the swivel bracket, turn the detector
case vertically in accordance with the chosen installation height.
Measure the distance (L) from the wall to the detector base edge with
the cover opened (Figure 2, Table 2).
- Fix the preset detector position and fasten it with the cap screw,
passing through the detector base to the swivel bracket.
Ceiling
Mounting
For the wall
mounting
Opening for the
cover latch
Port plug
For fastening
the base
To the swivel
bracket
PCB fixing
arm
For corner
mounting
Latch
Nut
Internal
sphere
Swivel
bracket base
External
sphere
Fastening
screw
Wall Mounting
L
2.3 m
12 m
0
0
Figure 1 – Detection zone pattern
4 Application
The detector may be installed in the flats, shops, offices, museums.
5 Scope of Delivery
Each Detector unit package contains the items listed in Table 2.