background image

1 Introduction

The detectors «Foton-10M», «Foton-10M-01» (hereinafter, the 

detector) is designed for detecting intrusion into the protected space 
and generating an alarm message by opening the relay output contacts.

The detector ensures tamper protection. The «Tamper» message is 

generated by opening microswitch contacts.

The detector is resistant to the exposure of ambient light and radio 

interference, as well as to influence of small pets: mice, rats, birds, 
placed in the cages at a distance not less than 2.5 m.

The detector is compact, attractive, simple in installation, and 

servicing. It is possible to install the detector on the wall or in the 
corner of the room.

2 Features

- Dual-element pyrodetector.
- Spherical Fresnel lens.
- Wide-angle detection zone.
- Immunity to insects intrusion to the pyrodetector. 
- Microprocessor-based signal processing.
- Extended speed range, detecteed by Foton-10M-01 (0.1 – 3 m/sec).
- Selectable modes of testing, sensitivity, alarm memory and led 

indication.

- Self-test mode.
- The detector is rated for switching to the DC power source with 

output voltage 10 – 15 V.

- Possibility to install the detector on the swivel bracket (supplied) 

for the detection zone repositioning. 

- Case tamper protection.

3 Specifications

Table 1

Parameter

Value

Detection zone

12 x10 m

Power supply, V DC

10 – 15 V, current 15 mА

Tamper output contacts

Closed – «Norm» message, current 

30 mА, voltage 72 V

Alarm message duration

Not less than 2 sec

Detection zones

 

9 long-range, 5 short-range

Sensitivity

Chosen by switch «1» (position 1/2)

Installation height range

2 – 5 m

Operating temperature range

minus 30 … + 50 

0

С

Relative humidity

95 % under 25 

0

С without moisture 

condensation

IP rating

IP41

Dimensions, max

90 х 60 х 50 mm

Weight, max

60 g

Detection zone pattern is shown in Figure 1.

PASSIVE INFRARED 

DETECTORS

 «FOTON-10M»,

«FOTON-10M-01»

Installation Guide

Table 2

Name

Version

-

-01

Passive infrared detector «Foton-10M»
Passive infrared detector «Foton-10M-01»
Swivel bracket
Screw 3-3х30.016 
Passive infrared detector «Foton-10M», 

«Foton-10M-01». Installation Guide

1 pc.

1 pc.

2 pcs.

1 copy

1 pc.
1 pc.

2 pcs.

1 copy

6 Choosing the Place of Installation

The detector is designed for operation in the closed areas. When 

choosing the detector installation place, take note of the fact that the 
detection zone may be limited by non-transparent objects (curtains, 
houseplants, cabinets, bookcases, etc), as well as glass and mesh 
partitions. There must be no windows, air conditioners, space heaters 
or heating radiators in the detector visibility range.

Recommended installation height:
- without swivel bracket – 2 – 3 m;
- by means of swivel bracket – 2.3 – 3 m (on condition that the 

detector tilt is adjusted).

Power supply and alarm loop wires should be located far enough 

from power feed cables.

7 The Detector Installation

- Unfasten the latch through the opening, which is situated downside 

the detector case by means of screwdriver and put off the detector 
cover (Figure 2).

- When installing the detector without swivel bracket it is necessary  

to put off the PCB by means of pushing up it’s fixing arm.

Figure 2 – The Detector Base and the Swivel Bracket

- Drill the holes in the base of the detector for wiring and fastening 

the detector (Figure 2).

- Choose the place of installation, mark the places for mounting 

holes with the regard to detector base (or swivel bracket) openings, 
drill the holes in the wall.

- Pass the wire through the mounting holes in the base, leave several 

centimeters of installation wire for it’s fastening inside the case.

- Fix the base of the detector case on the wall (swivel bracket) at 

the chosen place. 

- Put the PCB on its place.

Note

 – In case of swivel bracket using, unscrew the cap screw 

M3x20 from the swivel bracket sphere. Holding the assembled swivel 
bracket, fit the square bulge of the swivel bracket external sphere with 
the corresponded opening on the detector base. Turn the detector 
base to the left full point and then to the right. Plug in the screw to 
the opening in the top of the detector base and fix the connection by 
the screw. Set the detector base to the operating position and fasten 
it with the cap screw M3x20.

In case of the detector installation at 2 – 5 m height with keeping 

12 m detection zone, it is necessary:

- After the detector fastening to the swivel bracket, turn the detector 

case vertically in accordance with the chosen installation height. 
Measure the distance (L) from the wall to the detector base edge with 
the cover opened (Figure 2, Table 2).

- Fix the preset detector position and fasten it with the cap screw, 

passing through the detector base to the swivel bracket.

Ceiling 

Mounting

For the wall 

mounting

Opening for the 

cover latch

Port plug

For fastening 

the base

To the swivel 

bracket

PCB fixing 

arm

For corner 

mounting

Latch

Nut

Internal 

sphere

Swivel 

bracket base

External 

sphere

Fastening 

screw

Wall Mounting

L

2.3 m

12 m

0

0

Figure 1 – Detection zone pattern

4 Application

The detector may be installed in the flats, shops, offices, museums.

5 Scope of Delivery

Each Detector unit package contains the items listed in Table 2.