4.2  BOILER FRONT CONTROL

This icon indicates that boiler is in the OFF mode (anti-freeze system active). 
If the icon is not present s the boiler is in the ON mode.

This icon indicates the status of the boiler. 
If ON, boiler is in heating mode, if blinking there is a heating request.

This icon indicates the status of the boiler. 
If ON, boiler is in the DHW mode, if blinking there is a domestic hot water request.

DHW pre-heating: indicates that a pre-heating cycle has been activated.

Error: indicates any operating irregularities, together with an error code message.
This icon indicates the servicing operation. 
If ON, there is a system servicing operation in progress.
This icon indicates that the system is detecting the presence of a flame.

This icon indicates that the system is detecting the absence of a flame.

 + 

Water pressure low: these icons are present when the water pressure is low and needs to be re-
pressureized.

Icons

RESET

MENU

136°F

OK

MODE

Display

SOME  OF  THE  ICONS  SHOWN  ON  THE  CONTROL 

DEVICE  SCREEN  AT  THE  START-UP  PHASE  MIGHT 

NOT BE AVAILABLE DURING FUNCTIONNING.

THIS DEPENDS ON YOUR BOILER CONFIGURATIONS

DHW 

adjustment 

knob

The knob allows for the domestic hot water setpoint adjustment.

It also allows you to switch from one step to another and change the value of the selected 

parameter within the PROGRAMMING menu.

CH

adjustment 

knob

The knob allows for the central heating setpoint adjustment. 

It also allows you to switch from one step to another and change the value of the selected 

parameter within the PROGRAMMING menu

OK

MODE

MODE/OK 

button

It allows you to change the BOILER STATUS. You can also:

- navigate through the INFO menu

- select  parameters  inside  the  PROGRAMMING  menu  and  confirm  the  setting  of  the 

corresponding parameter value

RESET

MENU

MENU/RESET

button

It allows you to reset the boiler and enter in the INFO and PROGRAMMING menu. You can also:

- exit from the INFO and PROGRAMMING menu

- reset some error codes

Summary of Contents for Residence PRO 32 KIS

Page 1: ...o do so may result in an explosion or fire WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your...

Page 2: ...TIONSHIPS 10 4 13 ACCESS TO THE INFO MENU 10 4 14 LIGHTS AND FAULTS RESET PROCEDURE 10 5 HOW TO 12 5 1 HOW TO INCREASE THE SYSTEM PRESSURE 12 5 2 HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS 12 5 3 H...

Page 3: ...an of the boiler WARNING There is a risk of pipes freezing if the building is left unattendedforlongperiodsoftime inexcessof12hrs infreezing temperatures In the event the building will be unoccupied f...

Page 4: ...ivez les instructions intitul es Comment couper l admission de gaz de l appareil et appelez un technicien qualifi ou le fourmisseur de gaz pour ouvrir pour fermer 1 R glez le thermostat la temp rature...

Page 5: ...ed in the burner flame whose information allows the control board to operate the gas valve that regulates the fuel This sophisticated control system provides the auto regulation of the combustion so t...

Page 6: ...3 Flame sensor 14 Manual air vent hose 15 Manual upper air vent valve 16 Flue temperature sensor 17 Positive air pressure tube 18 Flue outlet 19 Air intake 20 Negative air pressure tube 21 Air pressur...

Page 7: ...ssure is low and needs to be re pressureized Icons RESET MENU 136 F OK MODE Display SOME OF THE ICONS SHOWN ON THE CONTROL DEVICE SCREEN AT THE START UP PHASE MIGHT NOT BE AVAILABLE DURING FUNCTIONNIN...

Page 8: ...nician or gas supplier After completing all operations required to prepare commissioning proceed as with the instructions in sections 4 6 and 4 7 sequentially to complete lighting the boiler 4 6 PROGR...

Page 9: ...onds the value will be confirmed automatically 9 9CAUTION Adjusting your maximum heating setpoint past the design temperature of your heat emitters may cause minor injuries or property damage Consult...

Page 10: ...mostat is set too high 4 13 ACCESS TO THE INFO MENU 9 9NOTICE Make sure you are in the Operation mode backlight ON see section 10 6 Using the boiler control panel it is possible to access the INFO men...

Page 11: ...st purging for 45 seconds at the fan s maximum speed It is not possible to release the error before the end of the post purging unless the boiler s power supply is switched off E022 iono alarm E023 io...

Page 12: ...maintained until the outlet water temperature reaches 131 F 55 C 9 9NOTICE The activation of the ANTI FREEZE function is indicated by the icon displayed on the front control circulator anti seize the...

Page 13: ...technician This appliance produces carbon monoxide CO gases The venting should never be taken apart by anyone other than a qualified technician The venting should not be separated Failure to comply m...

Page 14: ...he boiler and purge all air from system 19 p Power boiler back on 20 p Verify the polarity and ground of the power supply L N 120v L G 0v N G 0v 21 p Check incoming power to spark generator 120 vac 22...

Page 15: ...terior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign sh...

Page 16: ...ce accident corrosive atmospheres physical damage to the boiler alterations by unauthorized service operation contrary to the Manufactures instructions including annual cleaning or if the serial numbe...

Page 17: ...17...

Page 18: ...18...

Page 19: ......

Page 20: ...387 4663 Email info egproductsolutions com Professional Resources egproductsolutions com The Company is constantly working to perfect all of its production processes therefore the aesthetics and size...

Reviews: