9
20151139
GB
Technical description of the burner
4.1
Models available
4.2
Technical data
Tab. A
(1)
Reference conditions: Ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0m a.s.l.
(Hi = 11.86 kWh/kg)
4.3
Overall dimensions
4
Technical description of the burner
Designation
Voltage
Code
RDB 3.2 BX 32/50
1/230V/50Hz
20145385
Model
RDB 3.2 BX 32/50
Delivery
(1)
2.7 - 4.2 kg/h
Thermal output
(1)
32 - 50 kW
Fuel
Kerosene, viscosity 1.6
6 mm
2
/s at 20°C
Electrical supply
Single-phase
~
50Hz 230V ± 10%
Motor
Intensity 0.6 A – Output 150 W
Speed 2800 tr/min. - 294 rad/s
Capacitor
5
F
Ignition transformer
Secondary 18 kV – 25 mA
Pump
Pressure; 8
15 bar
Absorbed electrical power
0.16 kW
Protection level
IP 20
Net weight
12.2 kg
1 8 9
1 6 8
1 4 0
83
83
11
45
45
204
83
2 5 6
1 4 5 . 5
89
1 6 8
1 6 4
271
Fig. 1
20149460