9
5.3
T
echnical data
Description
Family PRO 42 KIS (*)
FAMILY PRO 42 IS (*)
Country destination
US/CAN
US/CAN
Input - Output
Maximum CH input rate (0 - 2,000 ft / 0 - 610 m)
Btu/hr
119,000
119,000
kW
34.88
34.88
Maximum DHW input rate (0 - 2,000 ft / 0 - 610 m)
Btu/hr
151,000
151,000
kW
44.25
44.25
Maximum CH input rate (2,001 - 5,000 ft / 610 - 1,524 m)
Btu/hr
119,000
119,000
kW
34.88
34.88
Maximum DHW input rate (2,001 - 5,000 ft / 610 - 1,524m)
Btu/hr
125,000
125,000
kW
36.63
36.63
Maximum CH input rate (5,001 - 7,500 ft / 1,524- 2,286 m)
Btu/hr
114,000
114,000
kW
33.41
33.41
Maximum DHW input rate (5001 - 7,500 ft / 1,524- 2,286 m)
Btu/hr
114,000
114,000
kW
33.41
33.41
Maximum CH input rate (7,501 - 10,000 ft / 2,286 - 3,048 m)
Btu/hr
105,000
105,000
kW
30.77
30.77
Maximum DHW input rate (7,501 - 10,000 ft / 2,286 - 3,048 m)
Btu/hr
105,000
105,000
kW
30.77
30.77
Minimum input rate (0 - 2,000 ft / 0 - 610 m)
Btu/hr
20,400
20,400
kW
5.98
5.98
Minimum input rate (2,001 - 5,000 ft / 610 - 1,524m)
Btu/hr
19,600
19,600
kW
5.74
5.74
Minimum input rate (5,001 - 7,500 ft / 1,524- 2,286 m)
Btu/hr
17,500
17,500
kW
5.13
5.13
Minimum input rate (7,501 - 10,000 ft / 2,286 - 3,048 m)
Btu/hr
15,500
15,500
kW
4.54
4.54
CH output rating (0 - 5,000 ft / 0 - 1,524 m)
Btu/hr
113,050
113,050
kW
33.13
33.13
CH output rating (5,001 - 7,500 ft / 1,524- 2,286 m)
Btu/hr
108,300
108,300
kW
31.74
31.74
CH output rating (7,501 - 10,000 ft / 2,286 - 3,048 m)
Btu/hr
99,750
99,750
kW
29.23
29.23
Energy guide
AFUE
%
95.0
95.0
Gas
Gas supply pressure Natural Gas (A)
in. W. C.
7.0
7.0
KPa
1.7
1.7
Min. gas supply pressure Natural Gas (A)
in. W. C.
3.5
3.5
KPa
0.9
0.9
Max. gas supply pressure Natural Gas (A)**
in. W. C.
10.5
10.5
KPa
2.6
2.6
Gas supply pressure LPG (E)
in. W. C.
11.0
11.0
KPa
2.7
2.7
Min. gas supply pressure LPG (E)
in. W. C.
8.0
8.0
KPa
2.0
2.0
Max. gas supply pressure LPG (E)**
in. W. C.
13.0
13.0
KPa
3.23
3.23
CH max gas rate natural gas (A)
(0 - 2,000 ft / 0 - 610 m)
ft
3
/hr
110.70
110.70
m
3
/hr
3.13
3.13
(2,001 - 5,000 ft / 610 - 1,524m)
ft
3
/hr
110.70
110.70
m
3
/hr
3.13
3.13
(5,001 - 7,500 ft / 1,524- 2,286 m)
ft
3
/hr
106.05
106.05
m
3
/hr
3.00
3.00
(7,501 - 10,000 ft / 2,286 - 3,048 m)
ft
3
/hr
97.67
97.67
m
3
/hr
2.76
2.76
DHW max Gas Rate natural gas (A)
(0 - 2,000 ft / 0 - 610 m)
ft
3
/hr
140.47
140.47
m
3
/hr
3.97
3.97
(2,001 - 5,000 ft / 610 - 1,524m)
ft
3
/hr
116.28
116.28
m
3
/hr
3.29
3.29
(5,001 - 7,500 ft / 1,524- 2,286 m)
ft
3
/hr
106.05
106.05
m
3
/hr
3.00
3.00
(7,501 - 10,000 ft / 2,286 - 3,048 m)
ft
3
/hr
97.67
97.67
m
3
/hr
2.76
2.76