2

AARIA START

WARNING

Keep the product purchase documents for tax purposes to be presented to the Authorised Technical Support upon request of 
a service call under warranty.

WARRANTY

R

 product has a 

Conventional Warranty (valid for Italy, Republic of San Marino, Vatican City), starting from the product's date of 

purchase.

The product must be used for its intended purpose, as stated by 

R

 for which it has been expressly manufactured.  

R

 

shall bear no responsibility, whether of a contractual or non-contractual nature, for any damage caused to people, animals, or 
property due to incorrect installation, adjustments, or maintenance, or improper use.

www.riello.it
Support // Authorized Support Centre

Find the nearest Authorised Technical Support by visiting the 
website

COMPLIANCE

 

R

 AARIA START heat pumps are compliant with the following European Directives:

 

Low Voltage Directive 2014/35/EU

 

Electromagnetic Compatibility Directive 2014/30/EU

 

RoHS Directive 2011/65/EU

 

ErP Directive 2009/125/EC and Regulation 2012/206/EC

 

WEEE Directive 2012/19/EU

 

F-Gas Regulation 2014/517/EU

Dear Technician,
We would like to congratulate you on having recommended a 

R

 unit: a modern product that is capable of ensuring maximum 

comfort at length, with a high degree of reliability, efficiency, quality and safety.
While your technical skills and knowledge will certainly be more than sufficient, this booklet contains all the information that we 
have deemed necessary for the device's correct and easy installation.

Thank you again, and keep up the good work.
 RIELLO

RANGE

Model

Code

AARIA START 25

20139542

AARIA START 35

20139546

AARIA START 50

20139548

AARIA START 70

20139550

ACCESSORIES
For the complete list of accessories and the information relating to their usage combinations, please refer to the catalogue.

Summary of Contents for AARIA START

Page 1: ...AARIA START SERIES R32 11 2017 cod Doc 0086715 rev 0 EN INSTALLATION AND TECHNICAL SERVICE INSTRUCTIONS...

Page 2: ...mps are compliant with the following European Directives Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU RoHS Directive 2011 65 EU ErP Directive 2009 125 EC and Reg...

Page 3: ...Place of installation p 12 2 7 Recommended distances p 12 2 8 Positioning p 13 2 9 Installation on old systems or systems in need of upgrading p 14 2 10 Refrigerating connection p 14 2 11 Wiring diag...

Page 4: ...operate carefully so as to avoid damaging the gas circuit and the fin bank 9 Do not place any inflammable object spray cans within a 1 metre radius from the air expulsion 9 According to EU Regulation...

Page 5: ...board that is triggered in order to adjust the flow of refrigerant gas or to stop the unit in case of overtemperature 40 C outdoor air temperature sensor which transmits the de tected value to the el...

Page 6: ...lve 15 Terminal board for electric connec tions 16 Electric panel cover 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 13 MODEL 35 1 Upper panel 2 Fan protection grille 3 Connections cover 4 Handle for handling...

Page 7: ...xpansion valve 15 Terminal board for electric connec tions 16 Electric panel cover 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 MODEL 70 1 Upper panel 2 Fan protection grille 3 Connections cover 4 Handle fo...

Page 8: ...ed air flow 3 40 4 20 6 00 8 10 kW Absorbed power at rated air flow 0 91 1 13 1 61 2 18 kW COP 3 71 kW kW Capacity at maximum air flow 4 60 5 40 6 90 10 00 kW Absorbed power at maximum air flow 1 50 1...

Page 9: ...tics Power supply 230 1 50 V Ph Hz Compressor Compressor Rotary Type Oil FW50S Type Oil charge 0 32 0 27 0 35 0 52 l Refrigerant R32 Type Refrigerant charge 0 70 0 72 0 95 1 20 kg Fan Fan Axial Type Q...

Page 10: ...ating it During the summertime the cycle is reversed and the thermal energy is extracted from the room air which is cooled and is delivered to the outdoor air A Outdoor unit B Indoor unit 1 Compressor...

Page 11: ...nical Service in English Warranty Spare parts labels energy label etichetta gas refrigerante contact sheet It is also supplied as kit Condensate outlet hose 4 x vibration dampers screws to connect ref...

Page 12: ...ch as it can be dangerous It must be disposed of ac cording to the regulations in force 2 6 Place of installation The location of R AARIA START devices must be determined by the system s designer or b...

Page 13: ...llow for the condensate discharge 9 If the device is installed in an area that is subject to heavy snowfalls place the unit in a raised position so as to pre vent the air flow from being blocked or in...

Page 14: ...1 2 Pollici Charge connection 1 2 Pollici Liquid line connection 6 35 mm Gas line connection 9 52 12 7 mm Charge connection 12 7 mm To access the cooling connections unscrew the fastening screw push d...

Page 15: ...facing down remove the flare nut on the unit connection insert it into the connection pipe flare the tube A Pipe A mm inches mm 6 35 1 4 9 1 9 52 3 8 13 2 12 70 1 2 16 6 15 88 5 8 19 7 1 Key 2 Torque...

Page 16: ...rvice it may be required to open and close the valves A Opening B Closing 1 Service connection blanking plug 2 On off valve shaft 3 Refrigerating pipe attachment 4 On off valve cover plug 5 Hex wrench...

Page 17: ...ut off valves closed A High pressure B Low pressure 1 Pressure gauge unit 2 Vacuum pump 3 3 way valve service connection A B 1 2 3 connect the vacuum pump to the pressure gauge unit connect the pressu...

Page 18: ...9 Carefully check for absence of leakages from the closing point of the plug 9 Do not force beyond the stop point to prevent damaging the shaft and causing leakage as a consequence 9 Once the check h...

Page 19: ...sensor CS TC Defrosting sensor Outdoor air sensor HW Power supply 230V 1F 50Hz CN17 MODEL 35 1 N 3 C 2 L GR GR MODULE BOARD MAIN PCB BOARD BLOCK R W B C W S V R U COMPRESSOR M BL OR P U V W W B AC N A...

Page 20: ...pressor sensor Defrosting sensor Outdoor air sensor TC CS HW 2 12 Electrical connection AARIA START It leaves the factory completely wired and only re quires a connection to the electrical power grid...

Page 21: ...to connect to the terminal board For the sizing of the electrical power cables and safety devices use the following table Model 25 35 50 70 Electrical characteristics Power supply 230 1 50 V Ph Hz Pr...

Page 22: ...and differential protection in stalled near the equipment connect the device to a properly functioning earthing sys tem make sure that the electrical power supply system is com pliant with the current...

Page 23: ...of the above listed controls have problems turn the device off and call the Technical Service immediately 9 Do not touch the device pipes to prevent potential burns 9 Take anti static precautions in...

Page 24: ...erations MUST be carried out under the fol lowing conditions cold device device NOT supplied with electric power suitable personal protection equipment 0 0 It is forbidden to open the access doors and...

Page 25: ...scharge The unit resets automatically when the temperature drops under 110 C After 3 consecutive interventions in 30 minutes the unit resets after problem resolution 9 Fan motor malfunction After 3 co...

Page 26: ...resets after problem resolution 24 Compressor motor overcurrent The unit resets automatically 25 Overcurrent protection for single phase of the compressor The unit resets after problem resolution In...

Page 27: ...rials shall be disposed of separately so as to re cover and recycle them Refrigerant and oil must be recovered and not dispersed into the environment At the end of its ser vice life the device shall b...

Page 28: ...39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicat...