background image

4

GENERAL

GENERAL

GENERAL SAFETY INFORMATION

 

9

Check that the product is complete, undamaged and as or-

dered as soon as you receive it. Report any discrepancies or 

damage to the 

R

 dealer who sold it.

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The product must be serviced at least once a year. Servicing 

must be arranged in advance with the 

R

 Technical Assis-

tance Service.

 

9

All servicing and repairs must be performed by a qualified 

heating engineer.

 

9

If water leaks from the storage cylinder, turn off the water 

supply and contact 

R

’s Technical Assistance Service or a 

qualified heating engineer immediately.

 

9

If the product is not going to be used for an extended peri-

od of time, contact the manufacturer’s Technical Assistance 

Service to have at least the following operations performed:

 

− Close the shut-off cocks for the domestic hot water circuit

 

− Shut down the boiler connected to the storage cylinder 

as instructed in its own manual

 

− Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

 

− Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

 

9

This instruction manual is an integral part of the product. It 

must be kept safe and must ALWAYS accompany the product, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you lose this manual, or-

der a replacement immediately. Keep the product purchase 

documents to be presented to the 

R

 authorised Technical 

Assistance Service to request a service call under warranty.

 

9

If the product is destined for use in a solar collector circuit, 

anti-freeze (propylene glycol, available separately) must be 

mixed with water in a percentage varying from 30% to 50% 

as instructed in the installation and maintenance manual 

for the 

R

 solar collectors.

PRECAUTIONS

The operation of any appliance that uses electrical power de-

mands that a number of fundamental safety precautions be re-

spected. In particular:

 

0

Never attempt to install the system without using suitable 

personal  protection  equipment  and without  following  all 

applicable occupational safety standards.

 

0

Do not touch the product when barefoot or wet if it has any 

electrical accessories installed in it.

 

0

Never  clean  or  service  the  storage  cylinder  without  first 

turning the mains power switch OFF to disconnect all elec-

trical accessories (if fitted) from the mains electricity supply.

 

0

Never pull, disconnect, or twist any electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not expose the storage cylinder to the elements. It is not 

designed for use outdoors.

 

0

If solar plant pressure decreases, it is forbidden to top up 

with only water as there is a danger of freezing and over-

heating.

 

0

Do not use connections or safety devices or fittings (expan-

sion vessels, pipes, insulation) that are not specifically de-

signed and tested for use in solar water heating systems.

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

General

Summary of Contents for 7000 ACI 60 PLUS

Page 1: ...cod Doc 0072586 rev 6 09 2017 7000 ACI PLUS EN INSTALLATION OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ories and details of their compatibil ity refer to the Catalogue ENGLISH Dear heating engineer We would like to congratulate you on having recommended a R buffer tank unit a modern product that s capa...

Page 3: ...autions 4 3 Description of the appliance 5 4 Identification 5 5 System layout 5 6 Technical specifications 6 7 Location of sensors 6 8 Overall dimensions and water fittings 7 INSTALLER 9 Unpacking the...

Page 4: ...and must ALWAYS accompany the product even if it is sold to another owner or transferred to another user or to another installation If you lose this manual or der a replacement immediately Keep the p...

Page 5: ...HER Modell Seriennummer Kode Baujahr Stromversorgung V Hz Speicherinhalt l 067670DE Erdschluss ist Vorschrift Obligatory ground connection Aarding verplicht W Stromaufnahme Max Betriebsdruck Speicher...

Page 6: ...r without insulation 790 790 1000 1100 mm Height with insulation 1725 1975 2090 2405 mm Height without insulation 1725 1975 2090 2405 mm Insulation thickness 30 mm Maximum operating pressure 6 bar Max...

Page 7: ...ent not supplied 1 1 2 F 2 F MI CH flow 3 F 4 F RI CH return 3 F 4 F SC Drain 1 F RC Return to boiler 3 F 4 F MC Outlet from boiler 3 F 4 F A 220 220 250 250 mm B 355 355 415 415 mm C 905 1030 1080 12...

Page 8: ...1500 1200 1200 2315 213 2000 1300 1300 2630 335 7000 ACI PLUS C A B H Gross weight kg 800 900 900 1875 112 1000 900 900 2125 168 1500 1200 1200 2240 190 2000 1200 1200 2555 305 10 HANDLING Once you ha...

Page 9: ...ks Make sure that the system is fitted with safety and con trol devices in accordance with applicable legislation and standards Make sure that the central heating circuit has been flushed out to remov...

Page 10: ...act on the environment and save energy before leaving for the weekend or a short break etc provided outdoor temperatures will remain above ZERO simply adjust the buffer tank s temperature control devi...

Page 11: ...Fit a pressure limiter Fit a flow reducer There are blockages or deposits in the buffer tank Check and clean as necessary Filling pump not functioning Check the pump The water temperature from the bo...

Page 12: ...The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice...

Reviews: