43
Parameter
name
Scrolling message
only if parameter P1.05 = 1 Description
I0.01
SCREED HEATING HOURS
Number of hours passed with screed heater function
I0.02
CH PROBE
Boiler delivery sensor value
I0.03
RETURN PROBE
Boiler return sensor value
I0.04
DHW PROBE
Domestic hot water probe value
I0.08
EXHAUST PROBE
Flue gas probe value
I0.09
OUTDOOR TEMP PROBE
Outdoor temperature sensor instantaneous value
I0.10
FILTERED OUTDOOR TEMP
Outdoor temperature fi ltered value used in the thermoregulation algorithm for
calculating the heating setpoint
I0.11
DHW FLOW RATE
For instantaneous boiler with fl owmeter
DHW SETPOINT
Only in case of OTBus connection
I0.12
FAN SPEED
Number of turns of the fan (rpm)
I0.13
MAIN ZONE OUTLET
Main zone fl ow sensor value (when P4.12 = 1)
I0.14
ZONE 1 OUTLET
Zone 1 fl ow sensor value (when P4.13 = 1)
I0.15
EXHAUST PROBE HOURS
Number of hours the heat exchanger has been operating in “condensing mode”
I0.16
MAIN ZONE SET
Main zone delivery setpoint
I0.17
ZONE 1 SET
Zone 1 delivery setpoint (when P4.23 = 1)
I0.18
WATER PRESSURE
System pressure
I0.30
COMFORT
Domestic hot water comfort (COFF, CSTD)
I0.31
SUN ON
Special functions active for high domestic hot water temperature inputs
I0.33
PCB ID
Electronic board card identifi cation
I0.34
PCB FW
Electronic board card fmw revision
I0.35
INTERFACE FW
Interface fmw
8.15 INFO MENU
Pressing key 3 on the display screen displays a list of informa-
tion regarding the operation of the boiler listed by parameter
name and value. Passing from the display of one parameter
to the next takes place by pressing respectively the keys
and
.
Pressing the key allows the selected parameter to be
displayed; pressing the key
returns you to the main screen: