background image

FAMILY

30

[EN] - 

ACCESSORIES

M2 L-N antifreeze heaters

CE8

TBT

(low temperature limit 

thermostat)

CE8

TA

(room thermostat)

CE8

OT+

CE8

SE

(outdoor temperature 

sensor)

F1=4A T

X1

X15

X4

X6

X11

1

6

X9

X19

X13 X8

X21

X2

X12

X14

1

5

1

12

1

10

4

1

1 3

1

5

1 4

X25

1

6

1

1

1

3

5

2

X3 X7

arancione

E.R.

AKM0x

SW1

marrone

blu

2

1

3

5

4

A

1 2

4

3

OPE

OPE

rosa

blu

marrone

1

X1

6

blu

P

marrone

marrone (+)

blu (-)

PWM

1

3

X8

M3

M2

blu

marrone

marrone

blu

F

L

N

F=3.15A F

X15

blu

V Hv

1

2

marrone

marrone

5

1

X4

C.S.A.

blu

TSC2

blu

EA

marrone

giallo/verde

N

F

X6

3

1

rosso (+24 Vdc)

giallo (B)

arancione (A)

nero (-)

rosso (+24 Vdc)

giallo (B)

arancione (A)

nero (-)

REC

nero (-) arancione (A) giallo (B) rosso (+24 Vdc)

- A B +

CE4

5

1

X14

rosso (alim.) +24Vdc

blu (HS)

rosa (PWM)

grigio (-)

V Lv

X13

1

4

1

10

X19

S.S.

1

3

TP

-t°

FS.

1

3

nero (alim.) +5Vdc

blu (sign.)

marrone (-)

rosso

blu (sign.)

viola (alim.) +5Vdc

arancione (-)

rosso

grigio

grigio

MOD

1

X9

12

-t°

-t°

-t°

T.L.A.

S.R.

S.M.

S.F.

rosso rosso

bianco bianco

grigio grigio

blu blu

4

3

2

1

5

rosso blu viola bianco

3V

X12

nero (TA)

nero (TA)

rosa (OT+)

rosa (OT+)

arancione (SE)

arancione (SE)

6

1

X11

1

2

bianco (TBT)

bianco (TBT)

X25

bianco (TBT)

bianco (TBT)

nero (TA)

nero (TA)

rosa (OT+)

rosa (OT+)

arancione (SE)

arancione (SE)

TBT

TA

nero

OT+ SE

CE8

bianco

B

C

[EN] - “L-N” POLARITY IS RECOMMENDED

4

15.6

[EN] - Wiring diagram

Blu=Blue 

 Marrone=Brown 

 

Nero=Black 

 Rosso=Red 

 

Bianco=White 

 Viola=Violet 

 

Rosa=Pink 

 Arancione=Orange 

 Grigio=Grey 

 Giallo=Yellow 

 Verde=Green

A

Gas valve

B

230V auxiliary

C

Voltage free contact input

AKM0X Control board

REC

Remote control panel

X1-X25 Connection connectors 

(accessories X2– X21)

S.W.1 Chimney sweep and interruption 

of the vent cycle

E.R.

Flame detection electrode

F

External fuse 3.15A F

F1

Fuse 4A T

M2-M3 Terminal board for external 

connections: 230V

CE4

External links connector: (-   A   

B   +) Bus 485

CE8

External links connector: 

TBT: Low temperature limit 

thermostat

TA: Room thermostat (contact 

must be free of voltage)

OT+: Open therm

SE: Outdoor temperature sensor

P

Pump

PWM PWM signal pump modulation

OPE

Gas valve operator

V Hv

Fan power supply 230 V

C.S.A. Semi-automatic heating system 

loading

TSC2 Ignition transformer

E.A.

Ignition electrode

T.L.A. Water limit thermostat

S.F.

Flue gas probe

S.M.

Temperature flow sensor on 

primary circuit

S.R.

Temperature return sensor on 

primary circuit

F.S.

Domestic hot water flow switch

S.S.

Domestic hot water circuit 

temperature probe

T.P.

Pressure transducer

MOD

Modulator

V Lv

Fan control signal

3V

3-way valve stepper servomotor

16.7

[EN] Overall dimensions

A

[EN] 

Weight

25 KIS

275 mm

35 kg

30 KIS

350 mm

41,5 kg

35 KIS

40 kg

EN

B

condensate drain

C

water - gas

5

CE4 Dir/mix zone controls

CE4

Hybrid modules

X2

Alarm remote control

X21

Zone valve or

additional pump

A

B

C

Summary of Contents for 20187642

Page 1: ...Family KIS EN INSTALLER AND USER MANUAL...

Page 2: ...ser also Warning This instructions manual contains data and information for both the user and the installer Specifically note that the user for the use of the appliance must refer to chapters Warnings...

Page 3: ...this case ventilate the room by opening the doors and windows close the fuel shut off device ask the Technical Assistance Service or professionally qualified personnel to intervene promptly a It is f...

Page 4: ...pe and consider any increase in the diameter of the pipe itself The condensation exhaust pipe must always have an adequate slope level to prevent the condensation from stagnating and its proper draina...

Page 5: ...and immediately before and after each change of direction curve b The boiler is supplied without the flue gas exhaust air suction kit since it is possible to use the accessories for condensing applia...

Page 6: ...e can exceed the static pressure of the collective air duct of 25 Pa in the condition in which n 1 boilers work at maximum rated heat input and 1 boiler at the minimum rated heat input allowed by the...

Page 7: ...e vent cycle Remove any air in the domestic system radiators zone manifolds etc using the bleed valves Once again check that the system pressure is correct ideally 1 1 5 bar and restore the levels if...

Page 8: ...is in progress number 1 is flashing This icon indicates that the circuit for domestic hot water production is enabled When a domestic hot water request is in progress the icon flashes The P at the to...

Page 9: ...LER CHANGE NAME INSTALLER PI PROPORTIONAL 5 0 99 SERVICE only mixing zones with ACTUATION BE16 PI INTEGRAL 10 0 99 SERVICE only mixing zones with ACTUATION BE16 VALVE RUN 120 sec 0 sec 120 sec SERVICE...

Page 10: ...request type TA and zone type HT 0 4 0 2 0 8 INSTALLER if EXTERNAL PROBE request type TA and zone type LT 2 0 1 0 5 0 INSTALLER if request type AMBIENT PROBE or REC10CH AMBIENT INFLUENCE 10 0 20 INSTA...

Page 11: ...DISABLE COOLING FUNCTION NOT ACTIVE FUNCTION ACTIVE FUNCTION NOT ACTIVE INSTALLER USE FOR DHW DON TUSE FOR DHW DHW FUNCTION NOT ACTIVE DHW FUNCTION ACTIVE DHW FUNCTION NOT ACTIVE INSTALLER if BE17 pre...

Page 12: ...t it has all the safety and control devices required by current regulations that the circulator rotates freely because especially after long periods of inactivity deposits and or debris can prevent fr...

Page 13: ...ZONE PARAMETERS WEATHER COMPENSATION INSTALLATION RANGE RATED CALIBRATION INSTALLER TECHNICAL SENSOR CALIBRATION ZONES MANAGER SYSTEM RESET INSTALLER INSTALLATION ADD ZONE MODIFY ZONE DELETE ZONE INS...

Page 14: ...URE C EXTERNAL TEMPERATURE C NIGHT COMPENSATION If a timer is connected to the ROOM THERMOSTAT input the NIGHT COMP function can be enabled as follows menu TECHNICAL WEATHER COMPENSATION CLIMATIC CURV...

Page 15: ...in standby again keeping the outlet temperature displayed If faults arise in ignition or operations the boiler performs a SAFETY STOP the triangle signalling faults will flash on the REC10CH To identi...

Page 16: ...Technical Assistance Centre 4 13 Gas conversion Conversion from a family gas to other family gas can be performed easily also when the boiler is installed This operation must be carried out by profes...

Page 17: ...l E042 water pressure transducer fault definitive E060 domestic hot water probe fault transitional E070 flow sensor faulty flow sensor overtemperature flow return sensor differential alarm transitiona...

Page 18: ...TECHNICAL Note After a reset it is necessary to carry out a new configuration of the system for details about this procedure see the following section 4 19 System configuration b This operation must b...

Page 19: ...in intact and to comply with prescriptions of current regulations it is necessary to render the appliance to systematic checks at regular intervals When carrying out maintenance work observe the instr...

Page 20: ...nnect the tubes A and B remove the clip C and remove the siphon Unscrew the bottom and top caps then remove the float Clean the parts of the siphon from any solid residues b Do not remove the safety s...

Page 21: ...EFAULT VALUE FACTORY SET MINIMUM VALUE MAXIMUM VALUE ACCESS LEVEL NOTES MENU SETTINGS USER TIME DATE USER DAYLIGHT SAVINGS TIME FUNCTION ACTIVE FUNCTION NOT ACTIVE FUNCTION ACTIVE USER LANGUAGE ITALIA...

Page 22: ...ed programme 8 2 3 MANUAL If MANUAL is selected the zone requests will be managed based on the setpoint set by the user 8 2 4 HEAT OFF If HEAT OFF is selected the zone requests will not be fulfilled N...

Page 23: ...0 INFO The INFO function can be used to display a series of data regarding the system ATTENTION The displayed data cannot be modified SCREED HEATER OPERATING HOURS DELIVERY PROBE RETURN PROBE DOMESTIC...

Page 24: ...TART THURSDAY USE THE ARROWS TO MODIFY ENTER START TIME ADD PERIOD END MAIN Once the operation completed the display will show 07 30 08 30 11 30 14 00 13 30 15 00 18 00 22 30 START THURSDAY ADD MODIFY...

Page 25: ...TURE WILL BE ADJUSTED WITH NEW TARGET SET POINT UNTIL 09 04 2021 ON 13 15 1 ZONE1 CONFIRM CANCEL 00 30 YOU ARE ACTIVATING COMFORT MODE ENTER TIME DURATION IN HOURS USE THE ARROWS TO MODIFY 1 ZONE1 26...

Page 26: ...Maximum pressure bar 8 8 8 Minimum pressure bar 0 15 0 15 0 15 Quantity of hot water with t 25 C 30 C 35 C l min 15 1 12 5 10 8 18 1 15 1 12 9 20 8 17 4 14 9 DHW minimum capacity l min 2 2 2 Selectio...

Page 27: ...ith reference to Delegated Regulation EU No 811 2013 the data in the table can be used for completing the product card and the labelling for ambient heating appliances for mixed heating appliances for...

Page 28: ...ivery 34 Hot water 35 Gas 36 Heating return 37 Cold water 2 21 AF AC M R 20 19 1 6 6 8 9 5 4 6 7 3 2 18 15 14 13 12 11 10 16 17 15 3 Residual head of circulator Fig 3 A B C Residual head mbar Flow rat...

Page 29: ...entering a value 10 the circulator speed will change to achieve a system flow rate with the aim of maintain ing the T of 10 C upstream and down stream of the exchanger 3 CIRCULATOR IN MAXIMUM FIXED S...

Page 30: ...Wiring diagram Blu Blue Marrone Brown Nero Black Rosso Red Bianco White Viola Violet Rosa Pink Arancione Orange Grigio Grey Giallo Yellow Verde Green A Gas valve B 230V auxiliary C Voltage free contac...

Page 31: ...from 60 100 to 80 80 110 65 65 1 1 5 90 bend 60 100 60 100 horizontal 10 horizontal 6 horizontal 6 1 3 1 6 105 vertical 11 vertical 7 vertical 7 90 bend 80 125 80 125 25 15 15 1 1 5 130 adaptor from 6...

Page 32: ...T OPTION 4 and SYSTEM INFO INSTALLATION WEATHER COMPENSATION RANGE RATED TECHNICAL INSTALLER 5 PARAMETERS CALIBRATION and ANTI CYCLE FUNCTION RESET CH TIMERS DHW THERMOSTAT PARAMETERS INSTALLER 6 PUMP...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Cod 20187595 09 21 Ed 3...

Reviews: