52
NexPolar
Table of functions and user parameters
Function
Param-
eter
Description Icon
Value
range
Set
value
Min Max
Mode
1
This parameter allows you to select the mode
0. Off
2. Cooling
3. Heating
Current mode
-
-
0
Homeantifreeze
2
This parameter enables the ambient antifreeze option when the
system is off:
1. NO. Disabled
2. YES. Enabled
antifreeze: 1
2
1
Ambient antifreeze tem-
perature
3
This code allows you to select the temperature threshold below
which the ambient (0/+ 2 °C hysteresis) antifreeze starts
°C 6°C
12°C
6°C
Set point adjustment
4
Changing the water set point on the basis of the temperature
taken by the thermostat
°C -5°C
+5°C
0°C
frequency reduction
mode
5
This code provides the information whether the mode is activated:
Night/Reduction of the frequency
1. Not active
2. Active
1
2
1
Frequency reduction
6
Value of the compressor's frequency reduction in %
50% 100%
100%
Room mode
7 Lock The control panel displays these parameters
1. At home
2. Night
3. Away from home
Arrow depending
on the Touch 'N
Go selected
1
3
1
Room control set point
8 Lock This code is the control room set point determined by pressing the
home, night, away buttons
°C 12°C
38°C
20°C
Room set point
9 Lock This is the room air temperature read by the thermostat sensor
°C
-20°C 50°C
Relative humidity value
from the sensor
10 Lock This is the relative humidity value from the thermostat sensor
%
0
100
Outdoor temperature
11 Lock Outdoor Temperature measured by the sensor °C
-30°C 90°C
Outdoor temperature -
GMC
12 Lock Outdoor temperature read by the GMC board
°C
-20°C 65°C
Room sensor tempera-
ture adjustment
13
Correction of the temperature read to correct errors due to the
position of the thermostat.
°C -5°C
5°C
0°C
Day period
14
This parameter speci
fi
es the number of periods per day that should
be activated for the timing programme:
2
4
6
2
6
4
"At home" temperature
in heating mode
15
AT HOME set point temperature in heating mode
°C and the At
Home arrow
12°C 38°C 20°C
"At home" temperature
in cooling mode
16
AT HOME set point temperature in cooling mode
°C and the At
Home arrow
12°C 38°C 24°C
“Night” temperature in
heating mode
17
NIGHT set point temperature in heating mode
°C and the
night arrow
12°C 38°C 18°C
“Night” temperature in
cooling mode
18
NIGHT set point temperature in cooling mode
°C and the
night arrow
12°C 38°C 26°C
“Away from Home”
temperature in heating
mode
19
AWAY FROM HOME set point temperature in heating mode
°C and the away
from home arrow
12°C 38°C 15°C
“Away from Home”
temperature in cooling
mode
20
AWAY FROM HOME set point temperature in cooling mode
°C and the away
from home arrow
12°C 38°C 28°C
Room set point
21 Lock Room set point
°C
12°C 38°C
20°C
Last alarm code
22 Lock Shows the last alarm code
-
-
Alarms log
23 Lock Shows the 4 most recent error codes
-
-
In case of parameters which are read-only and cannot be edited by user, key pad lock ( Lock) icon is displayed on the screen.