4.3 vertical wall installation
The unit comes with plates for fixing to the wall.
Proceed as follows to position the unit:
Drill the wall.
Insert the expansion plugs.
Fix the mounting brackets supplied to the unit.
Secure the unit by tightening the expansion plug screws.
The unit must only be installed indoors.
Respect the clear space on the side of the water and
electrical connections and ensure sufficient access for
future maintenance and repair operations. Ensure an
unrestricted air intake if at all possible.
Ensure an unrestricted air intake if at all possible.
To favour the drainage of condensate, install the unit at
a 3 mm downward slope towards the condensate drain
point.
It
4.3 Installazione verticale a parete
L’unità è già corredata di piastre per il fissaggio a muro.
Per posizionare l’unità:
Eseguire la foratura a muro.
Inserire i tasselli ad espansione.
Fissare all’unità le staffe di ancoraggio fornite a corredo.
Bloccare l’unità serrando le viti dei tasselli ad espansione.
L’installazione deve essere effettuata all’interno degli edi-
fici.
È necessario riapettare le distanze minime sul lato dei col-
legamenti idraulici ed elettrici e conservare l’accessibilità
per le future operazioni di manutenzione o riparazione.
Garantire una aspirazione possibilmente libera.
Allo scopo di favorire il regolare deflusso della condensa si
consiglia di montare la macchina inclinata di 3 mm verso
lo scarico condensa.
Modello / Model
09
15
17
21
24
36
43
A
mm
75
75
75
117,5
175
175
175
B
mm
675
1035
1035
1135
1375
1375
1375
B
Ø10