Cleaning, maintenance and care
56
Rieber GmbH & Co. KG
8.7.3
Note on cleaning the fan unit
Example: Left technical compartment
1
Radial fan
2
Diode of the plasma generator
➢
Unplug the mains plug of the radial fan/plasma generator assembly.
➢
Remove the assembly if necessary by sliding it along the guides, and place it on a soft surface.
➢
Eliminate any traces of grease. Then rub dry.
➢
WARNING
Leave the active carbon filter dry, keep away from moisture.
➢
Clean the soiled
surfaces of the radial fan
with a
hot cloth slightly dampened
with a
mild
detergent diluted in water. After cleaning, rub surfaces dry with a
soft cloth
.
➢
Install again in the reverse order.
8.7.4
Note on cleaning the plasma generator
At least every 3000 hours of operation:
Clean plasma generator
Failure to clean the
Diode
(2) on the plasma generator can cause unpleasant odours when using the
appliance, due to malfunction. See previous image.
➢
Pull the fan unit forward.
➢
Clean the diode on the plasma generator; For this, use a scratch-free cloth.
Use a little alcohol-based liquid if necessary, then rub dry.