Control temperature 0 - 30°C
The water temperature measured by the control EC sensor.
Monitor temperature 0 - 50°C
The water temperature measured by the monitor EC sensor.
Pre-measurement temperature 0 - 50°C
The water temperature measured by the pre-measurement EC sensor.
Pre-blending temperature 0 - 50°C
The water temperature measured by the pre-blending EC sensor.
Control percentage 1 0 - 100 %
The percentage of the cycle time that the relevant dosage valve is open.
Pre-blending control percentage -100 - 100 %
The percentage of the cycle time that the mixing valve will be actuated.
4.15
pH control activities
Pre-set setpoint
Calculated setpoint
Control pH
Monitor pH
Control value (%)
Ratio of dosage valve 1 - 8(%)
Path: Display summaries>pH control activities
Pre-set setpoint 0 - 10
The pre-set pH setpoint of the irrigation water. This is the target value that has been
entered into the system. This pH setpoint applies to all pre-set valves in the valve
group.
Calculated pH setpoint 0 - 10
The calculated pH target value of the irrigation water. This is the actual target value
that the controller will aim to reach.
Measured control pH
The measured pH value based on which the controller will aim to reach the calculated
pH setpoint.
Measured monitor pH
The pH value measured by the monitor sensor (i.e. the second pH sensor).
Control percentage 1 0 - 100 %
The percentage of the cycle time that the relevant dosage valve is open.