MACHINE_ERR_06
Error
Code
Suggested Cause
Action
06
Timeout error on the node authentication
Adjust the value of SP5-741-001 to
prolong the timeout for node
authentication.
MACHINE_ERR_07
Error
Code
Suggested Cause
Action
07
Multiple destinations are set in the Client-side
Machine.
In the Client-side Machine, execute
SP5-801-021 to clear AICS memory
MACHINE_ERR_08
Error
Code
Suggested Cause
Action
08(1)
• A Client-side Machine connects to other
Client-side Machine.
• The Client-side Machine not registered in
the Remote Machine as destinations.
• Connect to the Remote Machine.
• Register the Client-side Machine to
the Remote Machine as a
destination.
08(2)
• A Remote Machine connects to other
Remote Machine.
• Wrong Remote Machine registered in
the Client-side Machine.
• Connect to the Client-side
Machine.
• Check what Remote Machine
registered in the Client-side
Machine.