Bit Switches - 4
• Do not adjust a bit switch or use a setting that is described as "Not used", as this may cause the
machine to malfunction or to operate in a manner that is not accepted by local regulations. Such
bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List printed by
the machine.
G3 Switches
G3 Switch 00 (SP No. 1-105-001)
No
Function
Comments
0
1
Monitor speaker during communication (tx
and rx)
(0, 0): The monitor speaker is disabled all
through the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that
you reset these bits after testing.
Bit 1
Bit 0
Setting
0
0
Disabled
0
1
Up to Phase B
1
0
All the time
1
1
Not used
2
Monitor speaker during memory
transmission
0: Disabled 1: Enabled
1: The monitor speaker is enabled during memory
transmission.
3-5 Not used
Do not change the settings.
6
Dedicated G3 line mode selection
0: Off 1: On (Dedicated)
Set this bit to 1 when you wish to dedicate a line
for G3.
7
Not used
Do not change this setting.
G3 Switch 01 (SP No. 1-105-002)
No
Function
Comments
Bit Switches - 4
133
Summary of Contents for Type M12
Page 1: ...Fax Option Type M12 Machine Code D3A5 Field Service Manual July 2014 Subject to change...
Page 2: ......
Page 10: ...8...
Page 22: ...2 Remove the controller cover A x 4 3 Remove the controller rear cover A x 5 1 Installation 20...
Page 50: ...2 Replacement and Adjustment 48...
Page 84: ...3 Troubleshooting 82...
Page 218: ...5 Detailed Section Descriptions 216...
Page 226: ...MEMO 224 EN...