Data Overwrite Security Unit Installation
Installation
• The correct number and type for this installation is Type L. Do not attempt to install any other type
(Type C, Type D, for example).
• The SD card that holds the DOS application must always reside in SD card slot 1. (This can be the
original SD or another SD card where the DOS application has been moved with SP5873.)
1. If the machine is on, turn off the main power switch.
2. Disconnect the network cable.
3. Turn the main power switch on.
4. Turn the operation switch and main power switch off.
5. Remove the SD card slot cover (
x1).
6. Insert the DOS SD card into Slot 1.
7. Reconnect the network cable, if the network is connected to the copier.
8. Turn the main power switch on.
9. Enter the SP mode and do SP5878 and push [#Enter] to enable the DOS application.
10. Go out of the SP mode, turn the operation switch off, then turn the main power switch off.
Data Overwrite Security Unit Installation
15
1
Summary of Contents for S-P2
Page 1: ...Model S P2 Machine Code M001 SERVICE MANUAL September 2008 Subject to change ...
Page 2: ......
Page 12: ...10 ...
Page 15: ... Never place anything on the power cord Installation Requirements 13 1 ...
Page 22: ...2 Preventive Maintenance 20 2 ...
Page 36: ...3 Replacement and Adjustment 34 3 ...
Page 49: ...Main Motor 1 Left cover Left Cover 2 Main motor A x 4 x 1 Main Motor 47 3 ...
Page 54: ...3 Replacement and Adjustment 52 3 ...
Page 56: ...4 PSU fan with the bracket A x 1 x 2 5 PSU fan B x 2 3 Replacement and Adjustment 54 3 ...
Page 82: ...4 Troubleshooting 80 4 ...
Page 166: ...5 Service Tables 164 5 ...
Page 197: ... Any operation panel keys pressed Image Fusing and Paper Exit 195 6 ...
Page 207: ...Controller Specifications Controller Specifications 205 7 ...
Page 208: ...Controller Board 1 DDR DIMM I F 7 Specifications 206 7 ...