PC Calibration
After replacing the Main Board, PC Calibration should be done as well.
• Test equipment: video generator
• Test signal analog: 800 x 600@60Hz
• Test Pattern:94% White (up)/6% Black (down) (See below.)
Calibration Procedure
1.
Get into service mode. (
page 68 "How to Enter the Service Mode"
)
2.
Choose "Analog Settings" and press the "Enter" button.
3.
Select "PC Calibration".
When "Success" appears, it means "PC Calibration" is OK.
Calibration
75