• If the machine detects Vsg > 2.5 V, it will perform adjustments or issue SC401 as shown below, based
on the value of the Vsg reading.
ID Sensor Recalibration
Readings (V)
How the ID Sensor is Recalibrated
Vsg < 3.9
PWM value +0.5%
Vsg = 3.9 to 4.10
ID sensor is re-calibrated automatically with the stored PWM value.
Vsg = 4.1 to 4.2
PWM value -0.2%
Vsg = 4.2 to 4.5
PWM value -0.5%
Vsg = 4.5 to 4.8
PWM value -1.0%
Vsg > 4.8
SC401 occurs (ID Sensor Vsg Error). For more see Section "4. SC
Code Descriptions".
• If SP2804 is set to clean the charge corona wire during warm-up, Vsp/Vsg is measured after the wire
is cleaned.
• The machine measures Vsg after the machine is powered on or returns from the low power mode, if
SP2924 is set to "0" or "1". (The default is "0", which means that the machine measures Vsg after
power on when the fusing temperature is below 50
o
C.) For more, refer to “Service Tables”.
• If the machine is switched off and on after the warm-up sequence when Vsg is less than 2.5V, the
warm-up sequence is done, and the setting of SP2924 (Warm-up Control) is ignored.
Toner Density Control
Overview
This machine uses an ID sensor to control:
• Toner density
• Toner near end detection
• Toner end detection
The machine uses the ratio of Vsg/Vsp to find the quantity of toner that must be supplied to the drum.
To supply toner, the machine switches on the toner supply clutch to feed toner from the toner cartridge to
the development unit.
6. Details
396
6
Summary of Contents for Neptune-P1
Page 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Page 103: ...1 Installation 102 1...
Page 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Page 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Page 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Page 402: ...Toner End Recovery Flow Chart Development 401 6...
Page 449: ...6 Details 448 6...
Page 457: ...MEMO 456...