SC900 (Others)
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC900-00
D
Electronic counter error
The value provided by the electronic total counter is outside the normal
range.
• Unexpected NVRAM installed
• Defective NVRAM
• NVRAM data corruption
• Data is stored in an unexpected area due to external causes.
• The count requests made by SRM upon receiving the PRT have not
yet been processed.
Install an NVRAM device designed specifically for the model.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC920-**
B
Printer application error
A serious application error that stops the machine from operating is
detected.
• 920-00
At PM startup, no response was returned within the specified period
of time.
• 920-01
A time-out occurred during PM operation.
• 920-02
WORK memory acquisition failed.
• 920-03
The filter process cannot be started.
• 920-04
The filter process was aborted.
Turn the main power switch off and on.
Service Call
165
Summary of Contents for Gim-MF1a
Page 1: ...Model Gim MF1a b Machine Code M172 M173 Field Service Manual September 2014...
Page 2: ......
Page 32: ...2 Installation 30...
Page 46: ...2 Operation Panel A x 5 4 Replacement and Adjustment 44...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103...
Page 122: ...5 Operation Panel page 43 Operation Panel 4 Replacement and Adjustment 120...
Page 125: ...Service Program Mode 123...
Page 184: ...6 Troubleshooting 182...
Page 192: ...MEMO 190...
Page 193: ...MEMO 191...
Page 194: ...MEMO 192 EN...
Page 195: ...Model Gim MF1a b Machine Code M172 M173 Appendices September 2014...
Page 196: ......
Page 214: ...1 Appendices Specifications 18...
Page 299: ...MEMO 103...
Page 300: ...MEMO 104 EN...