Other Problems
Blown Fuse Conditions
Fuse
Rating
Symptom at Power On
115 V
210~230V
FU1
2A/125V
6.3A/250V
Anti-condensation heater does not operate.
FU101
12A/125V
6.3A/250V
No response.
FU103
6.3A/125V
6.3A/250V
SC510 is displayed.
FU104
6.3A/125V
6.3A/250V
Nothing displayed on LCD.
FU105
6.3A/125V
6.3A/250V
“Door Open” is displayed.
FU107
6.3A/125V
6.3A/250V
SC121 is displayed.
FU108
6.3A/125V
6.3A/250V
Finisher does not work.
FU109
6.3A/125V
6.3A/250V
“Door Open” is displayed.
FU110
6.3A/125V
6.3A/250V
SC510 is displayed.
FU111
6.3A/125V
6.3A/250V
Nothing is displayed on LCD.
Common Problems
Problem
Check
Inspect, Clean, Replace
Dirty Copies
Fusing Unit
Pressure roller
Jam – Fusing Unit
Fusing Unit
Hot roller
Jam – Fusing Unit
Fusing Unit
Hot roller strippers
Lines (black or white)
Around the Drum
Cleaning blade, cleaning brush
Misfeed – Fusing Unit
Fusing Unit
Hot roller
Offset
Fusing Unit
Hot roller
Poor separation
Transfer Belt Unit
Transfer belt, transfer belt cleaning blade
Other Problems
291
4
Summary of Contents for G148
Page 1: ...Model MT P2 Machine Code G148 SERVICE MANUAL 23 June 2006 Subject to change...
Page 52: ...10 Clamp 1 LCT B473 51 1...
Page 94: ...16 Set the hopper 13 in its holder Punch Unit B702 93 1...
Page 129: ...2 Preventive Maintenance 128 2...
Page 163: ...1 Open the front door 2 Pull out the internal dust filter A 3 Replacement and Adjustment 162 3...
Page 172: ...4 Development motor bracket D x 3 x 1 5 Development motor E x 4 Development Unit 171 3...
Page 237: ...3 Replacement and Adjustment 236 3...
Page 295: ...Install the paper feed unit 4 Troubleshooting 294 4...
Page 435: ...5 Service Tables 434 5...
Page 521: ...6 Details 520 6...