Discharge Plate
1.
Remove the transfer belt unit. See "Transfer Belt Unit Removal"
2.
Remove the shoulder screw and spring [A].
3.
Rotate the discharge unit up, then lift it straight up to remove it.
4.
Disconnect the three large tabs [B].
5.
Remove the bracket [C] (
x 1).
6.
Disconnect the 6 small seal case tabs [D].
7.
Remove the discharge plate [E].
Reinstallation
1.
Set the discharge plate and make sure that it is perfectly flat before re-connecting the tabs.
2.
Before re-attaching the bracket [C], make sure that all the tabs are connected.