4
195
Chapter 4 Master Making/Master Feed and Ejection Section
(5) Removing the Master Feed Unit
1. Open the scanner, and remove the master roll.
2. Remove the drum unit.
3. Remove the front cover.
4. Remove the scanner side cover L.
5. Remove the two screws to remove the cover F.
(S tight hexagon head WH rounded end screw
4 x 6)
6. Remove the two screws to remove the cover R.
(S tight hexagon head WH rounded end screw
4 x 6)
7. Disconnect the two connectors.
8. Remove the screw and disconnect the two
connectors.
Remove the inter lock unit.
(S tight hexagon head WH rounded end screw
4 x 6)
Please put a marking around the four screws
for cover R/F before remove it. Because it
makes you shorten the time to adjust the
position of master feed unit.
9. Disconnect the four connectors.
10. Remove the four screws to remove the
master feed unit.
(S tight hexagon head WH rounded end screw
4 x 6)
Cover R
Cover F
Connector
Screw
Screw
Screw
Screw
Screws
Connector
Inter lock
unit
Connector
3
Please put a marking around the four screws
for cover R/F before remove it.
Because it makes you shorten the time to
adjust the position of master feed unit.
REFERENCE
4P
20P
14P
30P
Screws
Connector
Master feed unit
30P
20P
4P
14P
Screws
Summary of Contents for DD 5450
Page 1: ...RICOH DD5450 DD5440 Machine Code C284 C283 Field Service Manual June 2016...
Page 2: ......
Page 15: ...Chapter 1 Dimensions 13 2 Dimensions 2 622 1405 555 228 1080 710 980 688 370 Unit mm...
Page 37: ...35 Chapter 2 Machine Installation 5 Touch OK DATE TIME is set 6 Touch END 1...
Page 170: ......
Page 262: ......