4.System Maintenance
91
System Software Installation Procedure
Overview
System software should be installed in the following cases:
You replace the HDD with a new one (on which the System Software is not installed)
You update to a more recent version of the system software (this is not necessary when you apply
a patch; it is necessary when you install a major version change)
You have trouble with the system software (e.g. software corruption) and the problem cannot be
solved by performing "Factory Defaults", restoring the backup files, or restoring the factory default
image.
About Methods for System Software Installation
There are 3 methods for installing the E-25C system software.
Restoring image file from E-25C HDD
Network Installation (Using a Network Cable)
USB Installation (Using a USB flash drive)
All of these methods will format the HDD before the system software is reloaded.
Fiery Installer Builder
System Software files
Restoring image file from the E-25C HDD
The factory default system files of E-25C already exist in the recovery folder of the E-25C HDD.
Restore this image by changing the service switch. For detailed instructions, see [Link To
Factory Default System Image File from the E-25C HDD Recovery Folder
It is recommended to try this method first, as it is the simplest method.
This method is not applicable in the following cases:
1) HDD was replaced with a new one.
2) A more recent system software version needs to be installed.
Summary of Contents for D3GF
Page 2: ......
Page 6: ......
Page 13: ...1 Installation 7 Installation Flow Chart Recommended installation steps are as follows ...
Page 46: ...1 Installation 40 If activation does not require a restart Server Option Client Option ...
Page 71: ...3 Replacement 65 Cover Removal Side Cover for the E 25C 1 Remove the side cover A ...
Page 93: ...4 System Maintenance 87 Command WorkStation For details refer to the Command WorkStation help ...
Page 187: ...7 Specifications 181 H 4 9 x 14 3 x 11 6 Weight 5 5 kg 12 2 lb ...