Adjusting Magnification
1. Place the test chart on the exposure glass. Make sure the test chart is aligned with the rear and left
scales on the exposure glass.
2. Make a copy.
3. Compare the copy with the original.
4. Adjust the main-scan and sub-scan magnifications. The original image [A] is magnified in the main-
scan direction [B] or in the sub-scan direction [C] when you specify a larger value.
• The diagrams show the paper on the copy tray. Note that the paper is output with the face down.
SP
Specification
SP2-102-001 (Main scan Mag.)
0
±
0.5%
SP4-008-001 (Sub Scan Mag.)
0
±
1.0%
DF Image Adjustment
• Perform the adjustment procedure in this section only when the ARDF is installed on the copier.
4. Replacement and Adjustment
138
Summary of Contents for D127
Page 1: ...Model S C5 Machine Code D127 D128 Field Service Manual 24 February 2012...
Page 2: ......
Page 14: ...Model S C5 201 12...
Page 28: ...1 Product Information 26...
Page 48: ...10 Remove the controller box 10 x 2 x 6 11 Remove the support bracket 11 x 3 2 Installation 46...
Page 54: ...11 Remove the controller box 11 x 2 x 6 12 Remove the support bracket 12 x 3 2 Installation 52...
Page 132: ...5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 4 Replacement and Adjustment 130...
Page 135: ...3 Registration sensor A x 1 hooks ARDF 133...
Page 158: ...5 System Maintenance Reference 156...
Page 198: ...6 Troubleshooting 196...
Page 206: ...MEMO 204 EN...
Page 207: ...Model S C5 Machine Code D127 D128 Appendices 26 November 2011...
Page 208: ......
Page 212: ...4...
Page 365: ...For the settings of the image quality see the copier SP mode table System Service Mode 157...
Page 366: ...3 Appendix SP Mode Tables 158...