3. Appendix: Service Call Conditions
Service Call Conditions
Summary
The "SC Table" section shows the SC codes for controller errors and other errors. The latter (not controller
errors) are put into four types. The type is determined by their reset procedures. The table shows the
classification of the SC codes.
Key
Definition
Reset Procedure
Controller
errors
CTL
The error has occurred in the
controller.
See “Troubleshooting Procedure” in
the table.
Other errors
A
The error involves the fusing unit. The
machine operation is disabled. The
user cannot reset the error.
Turn the main switch off and on. Reset
the SC (set SP5-810-1). Turn the main
switch off and on.
B
The error involves one or some
specific units. The machine operates
as usual, excluding the related units.
Turn the main power switch off and on.
C
The error is logged. The SC-code
history is updated. The machine
operates as usual.
The SC will not show. Only the SC
history is updated.
D
The machine operation is disabled.
You can reset the machine by turning
the main power switch or main switch
off and on. If the error occurs again,
the same SC code is displayed.
Turn the main power switch or main
power switch off and on.
After you turn the main power switch off, wait for one second or more before you turn the main power
switch on (
*
SC 670). All SCs are logged. The print log data (SP5-990-004) in SP mode can check the
latest 10 SC codes detected and total counters when the SC code is detected.
• If the problem concerns electrical circuit boards, first disconnect and then reconnect the connectors
before you replace the PCBs.
• If the problem concerns a motor lock, first check the mechanical load before you replace motors or
sensors.
29
3
Summary of Contents for AP-P2 G188
Page 1: ...Model AP P2 Machine Code G188 G189 Field Service Manual January 2009 Subject to change ...
Page 2: ......
Page 12: ...Electrical Component Defects 253 INDEX 255 10 ...
Page 22: ...1 Product Information 20 1 ...
Page 43: ...Item SP No Function Default Printer Installation 41 2 ...
Page 100: ...3 Preventive Maintenance 98 3 ...
Page 111: ...Left Cover 1 Left cover A x 6 Rear Cover 1 Rear cover A x 6 Exterior Covers 109 4 ...
Page 116: ...2 Filter B 3 Ozone filter C 4 Replacement and Adjustment 114 4 ...
Page 174: ...6 Development clutch K A x 1 4 Replacement and Adjustment 172 4 ...
Page 243: ...Controller Self Diagnostics 241 5 ...
Page 250: ...5 System Maintenance Reference 248 5 ...
Page 256: ...6 Troubleshooting 254 6 ...
Page 257: ...Model AP P2 Machine Code G188 G189 Appendices January 2009 Subject to change ...
Page 258: ......
Page 282: ...1 Appendix Specifications 24 1 ...
Page 286: ...2 Appendix Preventive Maintenance Tables 28 2 ...
Page 358: ...3 Appendix Service Call Conditions 100 3 ...
Page 374: ...5 Appendix Troubleshooting Guide 116 5 ...
Page 383: ...Sensor Locations Jam Detection 125 6 ...
Page 384: ...6 Appendix Jam Detection 126 6 ...
Page 392: ...7 Appendix Electrical Component Defects 134 7 ...