6. Troubleshooting
Utilities
Overview of Utilities
There are five utilities for setting and servicing these machines, but only three are used for all the
machines.
No.
Function
Start From
M101
M102
M103
1
Fax Maintenance
Operation Panel
No
No
Yes
2
Fax Test
Operation Panel
No
No
Yes
3
Engine Maintenance
Service Mode
Yes
Yes
Yes
4
Counter Information
Yes
Yes
Yes
5
Error History
Yes
Yes
Yes
• The first two utilities are for the M103 only because only the M103 has the fax feature.
• Items 3, 4, 5 are used for all machines of this series and are accessed with the Smart Organizing
Monitor (Service Mode).
Smart Organizing Monitor
The Smart Organizing Monitor screens are slightly different for each machine. For example, on the
Service Mode screen all the machines have the System and Printer tab but:
• M101 has the System and Printer tab but neither the Copy nor Fax tab
• M102 has the System, Printer, and Copy tab but not the Fax tab
• M103 has the System, Printer, Copy, and Fax tab
• In the screen samples used below to describe the Smart Organizing Monitor, are from the M103.
• Differences between the screens are noted when appropriate.
159
Summary of Contents for Aficio SP 100
Page 1: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Field Service Manual 26 December 2011...
Page 2: ......
Page 75: ...5 Free the harness x1 6 At the front disconnect the fusing unit x4 Basic Procedures 73...
Page 107: ...Solenoid 105...
Page 124: ...3 Disconnect and remove the board x5 Re installation 4 Replacement and Adjustments 122...
Page 135: ...1 Disconnect the speaker harness x1 2 Disconnect and remove the speaker x1 x2 Boards 133...
Page 139: ...7 Lay the rear cover on a flat surface 8 Disconnect the PSU x6 9 Remove the PSU Boards 137...
Page 143: ...9 Press the tab release and remove the board x1 AIO Terminals Boards 141...
Page 149: ...1 Separate both ends of the CIS from the cradles 2 Disconnect the CIS x1 Flatbed Scanner 147...
Page 156: ...4 Replacement and Adjustments 154...
Page 173: ...2 Enter the service mode to display the Service Mode screen 1 Fuser SC Detect Utilities 171...
Page 227: ...Model ME P1 MF1_ww Machine Code M101 M102 M103 Appendices 08 March 2012...
Page 228: ......
Page 230: ...2...