24 February, 1999
SCANNER UNIT
6-19
Replacement
Adjustment
6.3 SCANNER
UNIT
6.3.1 EXPOSURE LAMP REPLACEMENT
1. Remove the exposure glass (see “Covers, Fans, and Filters”).
2. Move the first scanner next to the opening in the frame.
3. Push the exposure lamp terminal [A] in the direction shown, and remove the
lamp [B].
4. Install the new lamp in the reverse order of disassembly.
NOTE: Do NOT touch the glass surface of the new lamp.
Ask the user to do the ACC procedure after replacing the lamp.
A259R005.WMF