Series PA/F, PA/S
Page
16
9510-010-en
Revision 18
TM 9549
Edition 11/2018
♦
Move actuation
515
into dead man´s position.
♦
Screw on spring bush
514
.
Note: Use your right hand to push actuation
515
up,
and at the same time use your left hand to tighten
spring bush
514
until the stop.
♦
Insert spring pressure
952
.
♦
Mount spring bonnet
513
with groove nut
509
. Note:
The thread of spring bonnet
513
must be just visible
at the bottom.
♦
Use a hook wrench to tighten groove nut
509
.
♦
Tighten both stud screws
920
of packing gland fol-
lower
503
.
♦
Tighten setscrew
904
in spring bush
514
.
♦
Standard: Screw in bottle connection
226
and se-
cure with clip
937
.
♦
Set stroke with star knob. See
Section 6.7
.
9.4 Assembling PA/S and
inserting the packing rings
♦
Screw stem
855
into bellows
206
.
♦
Insert guide ring
302
from the bottom into cover
106
,
and push the ring into the groove.
♦
Turn cover
106
around, and insert two packing rings
402
.
ATTENTION
: Offset overlapping from ring to ring by
60° to 90°.