Other possibilities of installing the pump are:
–
4-point installation
–
4-point installation with base plate.
HINWEIS!
As soon as additional installations are mounted, the stability of the entire unit installed
without a foundation must be checked.
2.5.3 Alignment of pump - coupling -motor standard version
WARNING!
The following information is of a general nature. If necessary, special notes of the cou-
pling and motor manufacturer are to be observed.
HINWEIS!
After attachment of the base plate on the foundation and connection of the pipes, the
alignment of the coupling must be carefully checked and, if necessary, the unit re-
aligned with the motor.
–
A coupling check and possible re-alignment is also necessary if the pump and motor are sup-
plied on a common base plate and aligned.
–
Prior to alignment undo the support bracket and then tighten it without stress.
–
The pump is to be aligned in all directions using a spirit level (on shaft/discharge nozzle)
(admissible position deviation max. 0.08” in/ft (0,2 mm/m).
–
A distance depending on the coupling used is to be observed between the pump and motor
shafts. See installation drawing.
–
Use supports in the direct vicinity of the bolts foundation/base plate.
DANGER!
Ensure that the unit cannot be started during work without the coupling guard.
2.5.4 Alignment of pump - motor close-coupled version
The following information is of a general nature. Special notes of the motor manufacturer are to be
observed.
MNK-B
–
Prior to alignment work, loosen the screwing in the lantern.
Safety and installation instructions for Richter pumps
Richter Pumpen /
pumps
Installation > Alignment of pump - motor close-coupled version
18