background image

Series KSE/F, KSE-C/F 

Page 

3

 

 
 

9530-001-en 

Revision   19 

TM  9549

 

Edition   11/2018

 

Relevant documents 

  Data sheet  

  EG-Declaration of conformity  

  Manufacturer Declaration ATEX Directive 

2014/34/EU 

  Manufacturer Declaration TA-Luft 

  Form  for  Safety  Information  Concerning  the 

Contamination QM 0912-16-2001_en 

On request : 

  Pressure spring table 

  Bellows operating ranges, TIS 0587-02-0006 

  VDTÜV data sheet "Safety valve 871" in German 

  VDTÜV data sheet "Safety valve 100" in German 

  Richter  publication  "Planning  and  using  chemical 

safety valves" in German 

 
 
 

Technical data

Manufacturer : 

Richter Chemie-Technik GmbH 
Otto-Schott-Str. 2 
D-47906 Kempen 
Telephone:  

+49 (0) 2152 146-0 

Fax: +49 (0) 2152 146-190 
E-Mail:  

[email protected] 

Internet:  

http://www.richter-ct.com

 

Designation : 

Bellows safety valve with angle-type valve body. They 
are  direct-acting  and  spring-loaded  and  classified  as 
standard  safety  valves  as  regards  their  opening 
characteristic. 
Series  

KSE/F

  

  design standard 

Series  

KSE-C/F

 

  design conical sealing 

surfaces 

Certified for vapours/gases and liquids: 
(DN 25 and DN 50 16 bar) . 
Certification number TÜV-SV...871 (S)D/G/(L)F. 
Standard  safety  valve,  design  and  operation  to 
German AD data sheet A2 (on pressure vessels), ISO 
4126 
Certified to Clean Air Act (TA Luft) 
Strength  and  tightness  (P10,  P11)  of  the  pressure-
bearing body tested to DIN EN 12266-1. 
Gas-tight (P12) in the seat  to DIN EN 12266-1,  
leak rate A 
Face to face: for DN 25/50, 50/80 and 80/100  
DIN EN 558-1 basic series 8, ISO 5752 series 8 
Flange  connecting  dimensions:  DIN  EN  1092-2,  type 

(ISO 7005-2 Typ B)  PN 16. 
or flanges drilled to ASME B16.5 Class 150 

Materials : 

Body material: 

Ductile cast iron EN-JS 1049 /  
ASTM A395 

Lining material: 

PFA/PTFE 

.../F 

On request:  antistatic   

…/F

-L 

Set pressure : 

Valve size 

KSE/F 

Set 

pressure 

[bar] 

Valve size 

KSE-C/F 

Set 

pressure 

[bar] 

25/50 

0.25 - 13 

--- 

--- 

50/80 

0.1 - 13 

--- 

--- 

80/100 

0.1 - 10 

80/100 

0.15 - 1 

100/150 

0.15 - 10 

100/150 

0.15 - 1 

Temperature range :    

-60 °C to +180 °C

 

See pressure-temperature diagram in 

Section 1.4

Valve size inlet/outlet in mm: 

KSE/F 

25/50, 50/80, 80/100, 100/150 

KSE-C/F  80/100, 100/150 

Weight:  

KSE/F  25/50 

 

ca. 15 kg 

KSE/F  50/80 

 

ca. 25 kg 

KSE/F, KSE-C/F  80/100  ca. 40 kg 
KSE/F, KSE-C/F  100/150  ca. 85 kg 

Installation position : 

A direction arrow on the shell indicates the direction of 
flow. See Section

 6.5

Dimensions and individual parts : 

See drawing in 

Section 10

 and options in 

Section 6.8

 

to 

6.13

Options : 

  Travel stop 

  Blocking screw 

  gas-tight design 

  Signal transmitter 

  Design for heavily permeating media (e.g. chlorine) 

  shorted lifting lever 

  without lifting lever 

  See also 

Section 6.8

 to 

6.13

Summary of Contents for KSE 100/150

Page 1: ...erved before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH 9530 001 en...

Page 2: ...on 11 6 6 Grounding 11 6 7 Installation 12 6 8 Blocking screw option 12 6 9 Gas tight design Option 12 6 10 Signal transmitter Option 12 6 11 Design for heavily permeating media Option 13 6 12 Shorten...

Page 3: ...t A2 on pressure vessels ISO 4126 Certified to Clean Air Act TA Luft Strength and tightness P10 P11 of the pressure bearing body tested to DIN EN 12266 1 Gas tight P12 in the seat to DIN EN 12266 1 le...

Page 4: ...2011 871 Certification number here 871 d0 Narrowest flow in mm here 40 S D G intended for discharging vapours gases L F intended for discharging liquids w Certified coefficient of discharge here 0 82...

Page 5: ...Tightening torque Nm in lbs KSE 25 50 4 x M8 10 89 KSE 50 80 4 x M8 12 106 KSE KSE C 80 100 4 x M8 12 106 KSE KSE C 100 150 8 x M8 15 133 1 4 Pressure temperature diagram When used in the minus temper...

Page 6: ...lastic lining Safety valves are intended to prevent inadmissible excessive pressures e g in piping systems pressure vessel plants and boilers Risks to people the environment and plants are thus avoide...

Page 7: ...revented e g by superimposing a layer of nitrogen It is recom mended to wait 1 hour before removing the valve from the plant in order to permit the elimination of static peak charges This means that t...

Page 8: ...ect the valve against impacts and collisions Never transport the valve using the lifting lever 238 See sectional drawings in Section 10 Place valve horizontally on the pallet with the discharge flange...

Page 9: ...case of prolonged storage individual packing with a desiccant may be necessary Pay attention to local site 5 4 Return consignments Valves which have conveyed aggressive or toxic media rinse and clean...

Page 10: ...ns The medium is to be discharged so that there is no risk to people and the environment The statutory provisions e g accident prevention regulations and the equivalents of the German Pollution Contro...

Page 11: ...lan and install safety valves 6 3 Valve connecting dimensions The main dimensions are contained in the dimensional drawing in Section 10 5 6 4 Flange caps and gaskets Contamination of or damage to the...

Page 12: ...crew This blocking screw may only be used for this purpose Always remove again immediately Damage to the valve could occur and pressure protection is then no longer provided The lead sealed cap nut 92...

Page 13: ...sert sleeve 308 cylindrical pin 561 1 pressure ring 124 bearing guide 305 and adjusting screw 538 are made of HC 4 See sectional drawing in sections 9 2 and 9 3 In addition with the sizes 80 100 and 1...

Page 14: ...er Option In order to exclude unauthorised activation the lifting lever 238 can be shortened a lever is supplied loose See Fig 13 the valve can be without a lifting lever the locking plate 539 is not...

Page 15: ...gainst mechanical damage by using flange caps See also Section 7 4 7 3 Recommissioning When recommissioning the valve make sure that all the appropriate steps as described in Section 6 1 to 6 7 and Se...

Page 16: ...n examination at the manu facturer s is necessary Medium is escaping at the bonnet Have the hex socket screws 914 1 not been tightened If after tightening the screws tightness still cannot be restored...

Page 17: ...recommend the installation of ex pansion joints or pulsation dampers 9 2 Cleaning Prior to starting any repair work the valve is to be thoroughly cleaned Even if the valve has been properly emptied a...

Page 18: ...livery over the stem 802 Screw the stem nut 534 against the distance sleeve The plug 204 is lifted off the seat 205 and the closing force becomes ineffective Loosen the bolts 901 1 936 1 936 2 and 920...

Page 19: ...accident The springs must firstly be completely relieved 9 7 1 Dismantling of the entire upper section Removal of the seat and plug To remove the seat and plug undamaged the plug 204 must be lifted o...

Page 20: ...See Fig 20 Fig 20 The KSE F can now be further dismantled See relevant Sections in 9 4 to 9 6 9 8 Assembly KSE F 50 80 80 100 100 150 KSE C F 80 100 100 150 Assembly the complete upper section with it...

Page 21: ...ing bonnet 513 and lift off the entire upper section Install pressure ring 124 in the thrust flange 117 observe Section 8 6 5 and screw bellows 206 with plug 204 and lifting aid 237 onto the spindle 8...

Page 22: ...gh as the lift given in the test certificate 9 9 2 Test pressure This test should take place on a test bench with a neutral medium such as air or water Regarding their suitability and precision the pr...

Page 23: ...lain 927 1 cap nut 929 1 prevailing torque type hex nut 932 x snap ring 934 1 lock washer 935 x lead seal 936 x tooth lock washer 938 1 hex head screw plug 939 x spring type pin 952 1 pressure spring...

Page 24: ...Series KSE F KSE C F Page 24 9530 001 en Revision 19 TM 9549 Edition 11 2018 10 2 Sectional drawing KSE F...

Page 25: ...Series KSE F KSE C F Page 25 9530 001 en Revision 19 TM 9549 Edition 11 2018 10 3 Sectional drawing KSE C F DN 80 100 100 150...

Page 26: ...Series KSE F KSE C F Page 26 9530 001 en Revision 19 TM 9549 Edition 11 2018 10 4 Views View X Detail Y upper spring plate Detail Z lower spring plate View X DN 100 150 View W DN 100 150...

Page 27: ...mensions in mm Flange connecting dimensions DIN EN 1092 2 type B ISO 7005 2 type B PN 16 or flanges drilled to ASME 16 5 Class 150 Nominal size Inlet Outlet DN1 S1 DN2 S2 KSE C d0 KSE d0 H L 25 50 25...

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ...The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to env...

Page 32: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Page 33: ...ch cleaning method radioactive3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence of...

Page 34: ...5241 2870 Email RichterShanghai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCed...

Reviews: