Materials : 

Body material: 

Ductile cast iron EN-JS 1049 /  
ASTM A 395 

Lining material:  

PFA 

…/F

 

on request:  

conductive lining 

…/F

-L 

Temperature range : 

See pressure-temperature diagram in Section 1.4. 

Operating pressure : 

from vacuum to max. 16 bar 

See pressure-temperature diagram in Section 1.4. 

Sizes : 

DN  

15, 20, 25, 40, 50, 65, 80, 100 

ASME  

½“, ¾“, 1“, 1½“, 2“, 3“, 4“

 

Weight: 

Nom. 

size 

15  20  25 

40 

50 

65 

80 

100 

ASME  

½“

 

¾“

 

1“

 

1½“

 

2“

 

--- 

3“

 

4“

 

ca. kg  

11 

17 

19 

20 

39 

44 

Installation position : 

Installation  position  horizontal.  Make  sure  that  the 
cover is on top. 
A direction arrow on the shell indicates the direction of 
flow. See Section 6.2. 

Dimensions and individual parts : 

See sectional drawing in Section 10 

Wear parts : 

  plug 

  seat 

 
 

1.1  Type plate, CE and body 

markings 

The stainless steel name plate is undetachably riveted 
to the body. 

If  the  operator  attaches  his  identification,  it  must  be 
ensured  that  the  valve  matches  the  application  in 
question.  

Example of name plate with CE marking: 

 

No CE marking is permissible for the sizes 15, 20 and 
25; the name plate therefore has no CE marking. 

 
 

Body identification 

The following are visible on the body according to DIN 
EN 19 and AD 2000 A4: 

  Nominal size 

  Rated pressure 

  Body material 

  Manufacturer's identification 

  Melt number/Foundry identification 

  Foundry date  

  Arrow for direction of flow 

 
 

1.2  Tightening torques 

All  screws  greased,  tighten  in  diametrically 
opposite sequence! 

The  tightening  torques  for  pipe  screws  and  body 
screws  mentioned  must  not  be  exceeded.  For  an 
exception,  see 

Section  8

,  Flange  connection 

valve/pipe is leaking. 

The following tightening torques are recommended. 

 

Pipe screws

, flanges to ISO/DIN 

 

Flange 

Nominal size 

screws 

Tightening torque 

[mm] 

[inch] 

[ISO/DIN] 

[Nm] 

[in-lbs] 

15 

½“

 

4 x M12 

55 

20 

¾“

 

4 x M12 

70 

25 

1“

 

4 x M12 

10 

90 

40 

1½“

 

4 x M16 

20 

175 

50 

2“

 

4 x M16 

26 

230 

65 

--- 

4 x M16 

40 

355 

80 

3“

 

8 x M16 

25 

220 

100 

4“

 

8 x M16 

35 

310 

 

Pipe  screws

,  flanges  to  ASME  Class  150  or  flanges 

ISO/DIN drilled to ASME Class 150 

Flange 

Nominal size 

screws 

Tightening torque 

[mm]  [inch] 

[ISO/DIN] 

[Nm] 

[in-lbs] 

15 

½“

 

4 x ½“

 

45 

20 

¾“

 

4 x ½“

 

55 

25 

1“

 

4 x ½“

 

70 

40 

1½“

 

4 x ⅝“

 

15 

135 

50 

2“

 

4 x 

⅝“

 

25 

220 

65 

--- 

4 x ⅝“

 

30 

265 

80 

3“

 

4 x ⅝“

 

45 

400 

100 

4“

 

8 x ⅝“

 

35 

310 

 

Summary of Contents for GR/F Series

Page 1: ...e strictly observed before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik Gm...

Page 2: ...ions 9 9 Maintenance 10 9 1 Dismantling 10 9 1 1 Replacing plug 10 9 1 2 Replacing seat 10 9 2 Assembly 10 10 Drawing 10 10 1 Legend 10 10 2 Sectional drawing 11 10 4 Dimensional drawing 12 Relevant d...

Page 3: ...e with CE marking No CE marking is permissible for the sizes 15 20 and 25 the name plate therefore has no CE marking Body identification The following are visible on the body according to DIN EN 19 an...

Page 4: ...r seats Nominal size Article No mm inch 15 20 9568 96 1011 25 1 9568 96 1001 40 1 9568 96 1002 50 65 2 9568 96 1003 80 3 9568 96 1004 100 4 9568 96 1005 Fig 1 1 4 Pressure temperature diagram 2014 68...

Page 5: ...ining items of equipment in accordance with the German Pressure Equipment Directive DGRL for the passage of fluids in the direction of the flow arrow provided on the body and for blocking the passage...

Page 6: ...the valve must be completely filled with medium at all times or else a potentially explosive atmosphere must be excluded by superimposing a layer of inert gas b Discharges outside the valve At the poi...

Page 7: ...ored in a dry vibration free and well ventilated room at as constant a temperature as possible Protect elastomers against UV light In general a storage period of 10 years should not be exceeded 5 2 Re...

Page 8: ...ection of flow must be observed when installing the valve It is indicated by a direction arrow on the valve body The closing operation is already initiated by the gravity of the closing element when t...

Page 9: ...e pressure temperature diagram can lead to damage 7 3 Shutdown The local regulations are to be observed when dismantling the valve Prior to undoing the flange connection ensure that the plant is depre...

Page 10: ...equired for assembling and dismantling the seat 205 The article numbers for the individual nominal sizes are listed in Section 1 3 The new seat is to be carefully protected prior to assembly The seali...

Page 11: ...Series GR F Page 11 9550 025 en Revision 14 TM 10477 Edition 05 2022 10 2 Sectional drawing...

Page 12: ...r flanges drilled to ASME B16 5 Class 150 DN 15 20 25 40 50 65 80 100 L 130 160 200 230 290 310 350 H 112 156 197 205 205 313 327 dimensions in mm Face to face to ANSI ISA 78 08 01 class 150 flanges t...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...ce GmbH Voraussetzung f r die G ltigkeit der Herstellererkl rung ist das Beachten und Einhalten der Betriebsanleitung meet the requirement of the eakage rate La 5 10 4 mgls m according to c ause 5 2 6...

Page 17: ...ls The laws are such as the Health and Safety at Work Act ArbSt ttV the Ordinance on Harzadous Substances GefStoffV BIOSTOFFV the procedures for the prevention of accidents as well as regulations to e...

Page 18: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Page 19: ...ch cleaning method radioactive3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence of...

Page 20: ...ai Info idexcorp com Internet www richter ct com Richter Pumps Valves Inc 406 State Street Cedar Falls 50613 IA USA Tel 1 319 268 8038 Fax 1 319 273 8157 Email RichterCedarFalls Info idexcorp com Inte...

Reviews: