11.6.3 Damping Filter (DMPONL)
The damping filter is a simple filter which adjusts the amount of time it takes for a change in weight to be processed through the
scale. The
DMPVL
parameter is a time interval specified in tenths of a second (10 = 1 second). This damping value is used to
determine the amount of time it takes for the scale to reach its final weight output. When
DMPVL
is set to ten, a transition from
0 lb to 500 lb on the scale takes one second. The closer the weight gets to its final amount, the slower the weight changes on
the display.
Figure 11-5. 500 lb Displayed Weight Progression
11.7 Regulatory Mode Functions
Regulatory
Parameter
Weight On
Scale
Tare In
System
Front Panel
Key Tare
Front Panel
Key Zero
NTEP
Zero
No
“000000”
Zero
Yes
Clear tare
Zero
Negative
No
No action
Zero
Yes
Clear tare
Zero
Positive
No
Tare
Zero
Yes
Tare
Zero
Canada
Zero
No
“000000”
Zero
Yes
Clear tare
Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Clear tare
Positive
No
Tare
Zero
Yes
No action
Clear tare
OIML
Zero
No
“000000”
Zero
Yes
Clear tare
Zero and Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Zero and Clear tare
Positive
No
“000000”
Zero
Yes
Tare
Zero and Clear Tare
None
Zero
No
“000000”
Zero
Yes
Clear tare
Clear tare
Negative
No
No action
Zero
Yes
Clear tare
Clear tare
Positive
No
Tare
Zero
Yes
Clear tare
Clear tare
Table 11-3. Tare and Zero Key Functions for REGULA Parameter Settings