680HE Synergy Indicator
50
Visit our website
7.10 Setpoint Commands
REGWORD
Regulatory word
GROSS
(default), BRUTTO
REG.RTARE
Round the Pushbutton Tare
NO,
YES
(default)
REG.RKTARE
Round the Keyed Tare
NO,
YES
(default)
REG.AZTNET
Perform AZT on Net value
NO
(default), YES
REG.MANUALCLEARTARE
Allows manual clearing of the tare value
NO,
YES
(default)
REG.TAREINMOTION
Allows Tare in Motion
NO
(default), YES
REG.ZEROINMOTION
Allows scale to be zeroed while in motion
NO
(default), YES
REG.UNDERLOAD
Underload weight value in display divisions
1–999999,
20
(default)
Command
Description
Values
BATCHNG
Batching mode
OFF
(default), AUTO, MANUAL
SP.KIND#
n
Setpoint kind
OFF
(default), GROSS, NET, -GROSS, -NET, ACCUM, POSREL, NEGREL,
PCTREL, PAUSE, DELAY, WAITSS, COUNTR, AUTOJG, COZ, INMOTN,
INRNGE, BATCHPR, TIMER, CONCUR, TOD, ALWAYS, NEVER
SP.VALUE#
n
Setpoint value
0.0–99999.0,
0.0
(default)
SP.TRIP#
n
Trip
HIGHER
(default), LOWER, INBAND, OUTBND
SP.BANDVAL#
n
Band value
0.0–99999.0,
0.0
(default)
SP.HYSTER#
n
Hysteresis
0.0–99999.0,
0.0
(default)
SP.PREACT#
n
Preact type
OFF
(default), ON, LEARN
SP.PREVAL#
n
Preact value
0.0–99999.0,
0.0
(default)
SP.PREADJ#
n
Preact adjustment percentage
0.0–100.0,
50.0
(default)
SP.PRESTAB#
n
Preact learn stability (in tenths of a second) 0–65535,
0
(default)
SP.PCOUNT#
n
Preact learn interval
1–65535,
1
(default)
SP.BATCH#
n
Batch step enable
OFF
(default), ON
SP.CLRACCM#
n
Clear accumulator enable
OFF
(default), ON
SP.CLRTARE#
n
Clear tare enable
OFF
(default), ON
SP.PSHACCM#
n
Push accumulate
OFF
(default), ON, ONQUIET
SP.PSHPRINT#
n
Push print
OFF
(default), ON, WAITSS
SP.PSHTARE#
n
Push tare
OFF
(default), ON
SP.ALARM#
n
Alarm enable
OFF
(default), ON
SP.ALIAS#
n
Setpoint name
Up to 8 alphanumeric characters,
SETPT
(default)
SP.ACCESS#
n
Setpoint access
OFF,
ON
(default), HIDE
SP.DSLOT#
n
Digital output slot
NONE
(default), 0
SP.DIGOUT#
n
Digital output
1–4,
1
(default)
SP.SENSE#
n
Digital output sense
NORMAL
(default), INVERT
SP.BRANCH#
n
Branch destination (0 = do not branch)
0–8,
0
(default)
SP.RELNUM#
n
Relative setpoint number
1–8,
1
(default)
SP.START#
n
Starting setpoint
1–8,
1
(default)
SP.END#
n
Ending setpoint
1–8,
1
(default)
SP.TIME#
n
Trip time
hhmm,
0000
(default)
SP.DURATION#
n
Trip duration
hhmmss,
000000
(default)
SP.ENABLE#
n
Setpoint enable
OFF,
ON
(default)
For setpoint commands ending with
#n
, n is the setpoint number (1-8)
Table 7-10. Setpoints Commands
Command
Description
Values
NTEP defaults shown for regulatory command values
Table 7-9. Regulatory Commands (Continued)