![Rice Lake Synergy 680HE Technical Manual Download Page 34](http://html1.mh-extra.com/html/rice-lake/synergy-680he/synergy-680he_technical-manual_1453958034.webp)
680HE Synergy Indicator
28
Visit our website
4.4.4.2 USB Menu
Figure 4-10. Communication – USB Menu
Parameter
Description
input
Input – Sets the input trigger type;
Settings:
CMD
(default) – Command: setting input trigger to command allows operation of EDP commands and can print
STRIND – Stream Industrial Scale Data: data is updated up to the configured sample rate; allows operation of
EDP commands and printing
STRLFT
–
Stream Legal for Trade Data: data is updated at the configured display update rate; allows operation of
EDP commands and printing
REMOTE
– Configures the port to operate as a serial scale input
termin
Outgoing Line Termination – Sets the termination character for data sent from the port;
Settings:
CR/LF
(default), CR
echo
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
ON
(default), OFF
respns
Response – Specifies if the port transmits replies to serial commands;
Settings:
ON
(default), OFF
eoldly
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next
formatted serial output (measured in milliseconds);
Enter value: 0–255,
0
(default)
Table 4-9. Communication – USB Menu Parameters
Setup
Comm
USB
input
termin
ECHO
ReSPNS
EOLDLY
Summary of Contents for Synergy 680HE