42
SCT-1100 Weight Transmitter
Parameter
Settings
Description
Define the functionality of each output
No function, the output is inactive
Setpoint on the gross weight
Functioning with hysteresis
(
parameter set at
)
Enables output function on gross weight; Two setpoints for each output must be set; one which disables
the output when the gross weight falls below it; and one which enables the output when the gross weight
is equal or greater than it
1. Press and hold
to enter the setpoint values for each configured output
2. Select
.
displays (output 1 – enabling setpoint)
3. Press
4. Enter the weight value. See
for key function
5.
Press
to confirm.
displays
(
output 1 – disabling setpoint
)
6. Press
7. Enter the weight value
8. Press
to confirm
9. Repeat steps 1 to 8 for all outputs
10. Slowly press
multiple times until
displays.
-Press
to confirm and store to the instrument memory
-Press any other key to cancel and exit without saving
Functioning without hysteresis
(
parameter set at
)
Enables output function on gross weight; One setpoint for each output is set
1. Press and hold
to enter the setpoint values for each configured output
2.
.
displays (output 1 – enabling setpoint)
3. Press
4. Enter the weight value; See
for key function
5. Press
to confirm
6. Repeat steps 1 to 5 for all outputs
7. Slowly press
multiple times until
displays.
-Press
to confirm and store to the instrument memory
-Press any other key to cancel and exit without saving
* The configuration of setpoints cannot be accessed if all outputs are set in the
functioning
mode, or if the selected functioning mode does not require entry of a setpoint value.
* With the instrument off or in standby outputs are normally open.
* The disabling setpoint must be equal to or less than the enabling setpoint. If the disabling
setpoint is set at a value greater than the enabling setpoint the instrument sets the setpoint to
zero until a valid value is entered.
* If the enabling setpoint is set at a value lower than the disabling setpoint, the enabling setpoint
is entered and accepted, however, the disabling setpoint will be set to zero.
* A 0 value is valid on both the enabling and disabling setpoints.
* A setpoint value remains active while modifying the setpoint until the new value is confirmed.
* The tare operations are active.
* These outputs are enabled by pressing a key (
,
,
,
or
); if the key press time is
greater than 2 seconds the output is disabled and remains disabled until the following pressing
of the key.
IMPORTANT:
the weight thresholds set with
are common to all connected scales; it is not possible to have different
thresholds for different scales. The value assumes the unit of measure and decimals of the selected channel; for example,
if 1000 is the set value, the setpoint values will be the following:
Channel
Unit of Measure
Decimals
setpoint Value
1
kg
3
1.000 kg
2
g
0
1000 g
3
kg
2
10.00 kg
4
g
1
100.0 g
Table 4-9. Output Menu
C
C
C