52567
RL1100EM
Portable Platform Scale
Mechanical-to-Electronic
Conversion Manual
Page 1: ...52567 RL1100EM Portable Platform Scale Mechanical to Electronic Conversion Manual...
Page 2: ...tions subject to change without notice July 1999 Contents 1 0 Introduction 1 2 0 Installation and Maintenance 2 2 1 Mechanical Components Removal 2 2 2 Indicator and Load Cell Installation 2 2 3 Final...
Page 3: ...tions up to 19200 bps Powered by six C size batteries for complete portability AC adapter for 115 or 230 Vac power Standby mode which can be configured to limit indicator power consumption when scale...
Page 4: ...pen end is perpendicular with the leg of load cell Tighten jam nut Figure 2 2 Load Cell Hardware Installation 2 Install jam nut on threaded adapter and turn adapter into top of load cell until thread...
Page 5: ...reinstall indicator back cover 16 Install cable tie on wrapped up load cell cable allowing sufficient cable to be able to tilt indicator head The scale is now ready for final adjustment and calibratio...
Page 6: ...er 1 4 in regular 7 4 21431 Load cell SBM 20000 100 1 5 50606 Threaded adapter 1 4 20 NC 1 6 50746 Coupling nut 1 4 20 NC 1 7 50605 Carriage bolt 1 4 20 NC x 2 in 1 8 51885 Mountplate weldment assembl...
Page 7: ...t caused by accident misuse neglect alteration improper installation improper repair or improper testing RLWS shall be the sole judge of all alleged non conformities Such equipment has not been modifi...