Fieldbus Options Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
81
10.6.4 Scale Status
10.6.5 Scale Error
NOTE: The scale error bit is always set to 1 unless one of the following errors occurs. At that time, the error bit is set to 0
until the error is cleared.
Table 10-12. Status Descriptions
Bit
Description
Bit Status
0
Net Weight Polarity
0 = Positive
1 = Negative
1
Gross Weight Polarity
2
Weight Stability
0 = Stable
1 = Motion
3
Underload Condition
0 = OK
1 = Under
4
Overload Condition
0 = OK
1 = Under
5
Push Button Tare Condition
0 = No
1 = Yes
6
Keyed Tare Condition
0 = No
1 = Yes
7
Gross Center of Zero
0 = COZ**
1 = COZ**
8
Display Mode
0 = Net
1 = Gross
9
Current Units
0 = Primary
1 = Other
10
Heartbeat - delay of 500 ms between on and off 0 = Off
1 = On
11
Scale Error
0 = Error
1 = OK
12
Accumulator Weight Polarity
0 = Positive
1 = Negative
12-31
Future Use
** Center of Zero
Table 10-13. Error Conditions
Error Condition
Configuration signature error
General configuration checksum error
Load cell data checksum error
Backup battery voltage low
Battery backed memory corrupt
Load cell A/D error
Tare data checksum error
Accumulator overflow error
Unable to write to non-volatile memory