![Rice Lake REVOLUTION 682 Synergy Plus Technical Manual Download Page 81](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947081.webp)
Fieldbus Options Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
73
10.0 Fieldbus Options Configuration
The 682 can be connected to SCT-2200 Fieldbus options to allow the 682 to communicate with a PLC with the necessary
network protocol. The following sections provide details on Fieldbus communications and describe the procedures required to
configure the available network protocols.
NOTE: The SCT-2200 Fieldbus options must be running firmware version 1.25 or higher to communicate with the 682.
10.1 Fieldbus Option Installation
1. Remove the backplate of the 682 (
).
2. Wire an RJ45 to blunt-end cable (not provided) to the J4 connector on the 682 CPU board.
NOTE: Maximum RJ45 cable length is 4,000 ft.
3. Connect the other end of the cable to one of the RS-485 RJ45 ports on the SCT-2200 Fieldbus module.
Figure 10-1. SCT-2200 Fieldbus Module Wiring
Table 10-1. Available SCT-2200 Fieldbus Options for the 682 Indicator
Part No.
Description
182591
Fieldbus, SCT-2200 EtherNet/IP Module
182592
Fieldbus, SCT-2200 PROFINET Module
212772
Fieldbus, SCT-2200 PROFIBUS DP Module
182596
Fieldbus, SCT-2200 DeviceNet Module
182597
Fieldbus, SCT-2200 CANopen Module
182598
Fieldbus, SCT-2200 EtherCAT Module
196694
Fieldbus, SCT-2200 Modbus TCP Module
Table 10-2. Pin Assignments
682 J4 Pins
SCT-2200 Fieldbus
Module RJ45 Pins
Wire Color
Wire Diagram
1-3 (Not Used)
6-8 (Not Used)
–
–
4
(Z)
5
(B-)
Blue
5
(Y)
4
(A+)
White/Blue
–
1-3 (Nut Used)
–
–
Pin
RJ45 Ports
6-8
Not Used
5
B-
4
A+
1-3
Not Used
Summary of Contents for REVOLUTION 682 Synergy Plus
Page 129: ......