![Rice Lake REVOLUTION 682 Synergy Plus Technical Manual Download Page 121](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947121.webp)
Appendix
© Rice Lake Weighing Systems
●
All Rights Reserved
113
16.7 Digital Filtering
Digital filtering is used to create a stable scale reading in challenging environments. The 682 allows selection of
Digital Rolling
Average Filtering
),
Adaptive Filtering
(
),
Damping
)
or
Raw
for configuration menu layout and the location of the Filter Chain Type
parameter.
The scale’s sample rate effects all types of filtering. The A/D sample rate is selected by the Sample Rate parameter. The A/D
sample rate is the number of weight readings the indicator takes per second. This can be 6.25, 7.5, 12.5, 15, 25, 30, 50, 60 or
120 hertz (readings per second). Set the A/D sample rate to the lowest setting required for the application. Lower settings result
in better stability.
B17
Configuration
=000 if current DECPNT=8888800
=001 if current DECPNT=8888880
=010 if current DECPNT=8888888
=011 if current DECPNT=888888.8
=100 if current DECPNT=88888.88
=101 if current DECPNT=8888.888
=110 if current DECPNT=888.8888
=111 if current DECPNT=88.88888
B18
Configuration
=000 if primary DECPNT=8888800
=001 if primary DECPNT=8888880
=010 if primary DECPNT=8888888
=011 if primary DECPNT=888888.8
=100 if primary DECPNT=88888.88
=101 if primary DECPNT=8888.888
=110 if primary DECPNT=888.8888
=111 if primary DECPNT=88.88888
B19
Configuration
=000 if secondary DECPNT=8888800
=001 if secondary DECPNT=8888880
=010 if secondary DECPNT=8888888
=011 if secondary DECPNT=888888.8
=100 if secondary DECPNT=88888.88
=101 if secondary DECPNT=8888.888
=110 if secondary DECPNT=888.8888
=111 if secondary DECPNT=88.88888
B20
Configuration
=000 if tertiary DECPNT=8888800
=001 if tertiary DECPNT=8888880
=010 if tertiary DECPNT=8888888
=011 if tertiary DECPNT=888888.8
=100 if tertiary DECPNT=88888.88
=101 if tertiary DECPNT=8888.888
=110 if tertiary DECPNT=888.8888
=111 if tertiary DECPNT=88.88888
<
wspec
[–] [0]
digit
[.[.][
digit
]]> Scale weight
Weight for the source scale.
wspec
is defined as follows:
wspec
indicates whether the weight is the current displayed weight (W, w), gross (G,
g), net (N, n) or tare (T, t) weight; Upper-case letters specify right-justified weights,
lower-case are left-justified
Optional /P, /S or /T suffixes can be added before the ending delimiter (>) to specify
weight display in primary (/P), secondary (/S) or tertiary (/T) units
[–] Enter a minus sign (–) to include sign for negative values
[0] Enter a zero (0) to display leading zeros
digit[.[.][digit]]
The first digit indicates the field width in characters; The decimal point only indicates a
floating decimal; A decimal point with a following digit indicates fixed decimal with
n
digits to the right of the decimal; Two consecutive decimals send the decimal point even
if it falls at the end of the transmitted weight field
<CR>
--
Carriage return
<LF>
--
Line feed
Table 16-3. Stream Format Tokens (Continued)
Format Identifier
Defined By
Description