![Rice Lake REVOLUTION 682 Synergy Plus Technical Manual Download Page 119](http://html1.mh-extra.com/html/rice-lake/revolution-682-synergy-plus/revolution-682-synergy-plus_technical-manual_1453947119.webp)
Appendix
© Rice Lake Weighing Systems
●
All Rights Reserved
111
16.5.3 Avery Weigh-Tronix Stream Format (
WTRONIX
)
Figure 16-3. Avery Weigh-Tronix Stream Data Format
16.5.4 Mettler Toledo Stream Format (
TOLEDO
)
Figure 16-4. Mettler Toledo Stream Data Format
Space
Polarity:
<+> for positive
"–" for negative
Six digits, right justified, floating decimal,
leading zeros are present
g for Gross
n for Net
<CR><LF>
or
<CR>
lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
oz = ounce
<space> = none
Space
<SP> <G/N> <POL> <wwwwww> <SP> <UNIT> <TERM>
<STX> <SWA> <SWB> <SWC> <wwwwww> <tttttt> <CR>
Status Word A
<CR> entered at end
of string
Status Word B
Status Word C
MUL1 MUL0
Parity
DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100
(2 fixed zeroes)
0 0 1 x 10
(1 fixed zero)
0 1 0 x 1
(No decimal point)
0 1 1 x 0.1
(1 decimal place)
1 0 0 x 0.01
(2 decimal places)
1 0 1 x 0.001
(3 decimal places)
1 1 0 x 0.0001
(4 decimal places)
1 1 1 x 0.00001 (5 decimal places)
Disp. Div.
MUL1 MUL0 M ultiplier
0 1 x 1
1 0 x 2
1 1 x 5
Even parity bit.
Requires EDP Port setup.
Status Word A:
Status Word C: ASCII 20h (space)
Even parity bit:
Requires EDP Port setup.
Status Word B:
0 = Gross Display Mode
1 = Net Display Mode
0 = Positive indicated weight value
1 = Negative indicated weight value
0 = In range
1 = Out of range
0 = Stable
1 = Motion
0 = lb
1 = kg
Even parity bit:
Requires EDP Port
setup.
Six digit Gross or Net weight, right justified,
dummy and leading zeros
Six digit Tare weight, right justified,
dummy and leading zeros
7
6
5
4
3
2
1
0
DP2
DP1
DP0
1
0
Parity
7
6
5
4
3
2
1
0
1
0
0
0
0
0
0
Parity
7
6
5
4
3
2
1
0
1
0
ASCII 002
Summary of Contents for REVOLUTION 682 Synergy Plus