7.6 Internet Setting Commands
7.7 Stream Setting Commands
Command
Description
Values
WIRED.MACID
Ethernet hardware MAC ID (read only)
xx:xx:xx:xx:xx:xx,
00:00:00:00:00:00
(default)
WIRED.DHCP
Enable Ethernet DHCP
ON
(default), OFF
WIRED.ENABLED
Enable wired Ethernet adapter
ON,
OFF
(default)
WIRED.IPADDR
Ethernet IP address
Valid IP xxx.xxx.xxx.xxx*,
0.0.0.0
(default)
WIRED.SUBNET
Ethernet subnet mask
Valid IP xxx.xxx.xxx.xxx*,
255.255.255.0
(default)
WIRED.GATEWAY
Ethernet gateway
Valid IP xxx.xxx.xxx.xxx*,
0.0.0.0
(default)
TCPC1.ECHO
TCP Client 1 echo
ON
(default), OFF
TCPC1.EOLDLY
TCP Client 1 end-of-line delay
0–255 (in 0.1 sec intervals),
0
(default)
TCPC1.IPADDR
TCP Client 1 remote server IP
Valid IP xxx.xxx.xxx.xxx*,
0.0.0.0
(default)
TCPC1.LINETERM
TCP Client 1 line termination
CR/LF
(default), CR
TCPC1.NAME
TCP Client 1 name
Up to 16 alphanumeric characters,
TCPC1
(default)
TCPC1.PORT
TCP Client 1 remote server port
1025–65535,
10001
(default)
TCPC1.RESPONSE
TCP Client 1 response
ON
(default), OFF
TCPC1.DISCTIME
TCP Client 1 disconnect time (in seconds)
0–60 (0= do not disconnect),
0
(default)
TCPC1.INPUT
TCP Client 1 input function
CMD
(default), STRIND, STRLFT, REMOTE
TCPS.ECHO
TCP Server echo
ON
(default), OFF
TCPS.INPUT
TCP Server input type
CMD
(default)
TCPS.LINETERM
TCP Server line termination
CR/LF
(default), CR
TCPS.NAME
TCP Server name
Up to 16 alphanumeric characters,
TCPS
(default)
TCPS.PORT
TCP Server port number
1025–65535,
10001
(default)
TCPS.RESPONSE
TCP Server response
ON
(default), OFF
USB.INPUT
USB input function
CMD
(default), STRIND, STRLFT, REMOTE
USB.LINETERM
USB line terminator
CR/LF
(default), CR
USB.ECHO
USB echo
ON
(default), OFF
USB.RESPONSE
USB response
ON
(default), OFF
USB.EOLDLY
USB end of line delay
0–255,
0
(default)
USB.PRINTMSG
USB print message
ON
(default), OFF
*
A valid IP consists of four numbers, in the range of 0 to 255, separated by a decimal point (127.0.0.1 and 192.165.0.230 are valid IP addresses)
Table 7-6. Ethernet TCP/IP and Wi-Fi Commands
Command
Description
Values
STRM.FORMAT#
n
Stream format
RLWS
(default), CARDNAL, WTRONIX, TOLEDO, CUSTOM
STRM.CUSTOM#
n
Custom stream definition
Up to 1000 alphanumeric characters
STRM.GROSS#
n
Mode token when streaming the Gross weight
Up to 8 alphanumeric characters,
G
(default)
STRM.NET#
n
Mode token when streaming the Net weight
Up to 8 alphanumeric characters,
N
(default)
STRM.PRI#
n
Units token when streaming Primary units
Up to 8 alphanumeric characters,
L
(default)
STRM.SEC#
n
Units token when streaming Secondary units
Up to 8 alphanumeric characters,
K
(default)
STRM.INVALID#
n
Status token when streaming an Invalid weight
Up to 2 alphanumeric characters,
I
(default)
STRM.MOTION#
n
Status token when the weight is in motion
Up to 2 alphanumeric characters,
M
(default)
STRM.POS#
n
Polarity token when the weight is positive
SPACE
(default), NONE, +
STRM.NEG#
n
Polarity token when the weight is negative
SPACE, NONE,
–
(default)
STRM.OK#
n
Status token when the weight is OK (not invalid, out
of range, at zero, or in motion)
Up to 2 alphanumeric characters
STRM.TARE#
n
Mode token when streaming the tare weight
Up to 8 alphanumeric characters,
T
(default)
STRM.RANGE#
n
Status token when the weight is Out of Range
Up to 2 alphanumeric characters,
O
(default)
STRM.ZERO#
n
Status token when the weight is at Center of Zero
Up to 2 alphanumeric characters,
Z
(default)
For commands ending with
#n
, n is the stream format number (1)
Table 7-7. Stream Formatting Commands