4.4.8 Setup – Setpoints Menu
Figure 4-16. Setup – Setpoints Menu
Parameter
Description
stptcfg
Setpoint Configuration – Access to configuration parameters and settings for up to eight setpoints;
Settings: SETPT 1-8
KIND
– Setpoint Kind:
Settings:
OFF
(default), GROSS, NET, -GROSS, -NET, ACCUM, POSREL, NEGREL, PCTREL,
PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG, COZ, INMOTON, INRANGE, BATCHPR, TIMER,
CONCUR, TOD, ALWAYS, NEVER
batchng
Batching – Batch sequence runs when set to AUTO or MANUAL;
Settings:
OFF
(default)
AUTO – Allows the batch sequence to repeat automatically once it has been started
MANUAL – Requires a BATSTRT input/command to run the batch sequence
Table 4-15. Setup – Setpoints Menu Parameters
Setup
setpnt
batchng
setpt 1
Setpt 2-8
stptcfg
kind
off
gross
net
-gross
-net
accum
posrel
negrel
pctrel
pause
delay
waitss
counter
autojog
coz
inmoton
inrange
batchpr
timer
concur
tod
always
never